首页 | 本学科首页   官方微博 | 高级检索  
     

丙烯酸酯压敏胶中残留单体的HPLC法测定
引用本文:胡婧,罗华菲,王雅珍,陈纯,王浩. 丙烯酸酯压敏胶中残留单体的HPLC法测定[J]. 中国医药工业杂志, 2010, 41(2)
作者姓名:胡婧  罗华菲  王雅珍  陈纯  王浩
作者单位:上海医药工业研究院,药物制剂国家工程研究中心,上海,201203
摘    要:建立了HPLC法同时测定丙烯酸酯压敏胶中三种残留单体--乙酸乙烯酯、丙烯酸乙酯和丙烯酸正丁酯的含量.采用C_(18)色谱柱,流动相为乙腈-水(40:60),检测波长210 nm.乙酸乙烯酯、丙烯酸乙酯、丙烯酸正丁酯分别在0.04~20、0.04~20、0.2~100μg/ml浓度范围内线性关系良好,平均回收率为99.6%、100.8%和99.4%,RSD小于2%:日内、日间RSD小于3%和5%.

关 键 词:丙烯酸压敏胶  残留单体  高效液相色谱  测定

Determination of Residual Monomers in Acrylic Pressure Sensitive Adhesive by HPLC
HU Jing,LUO Huafei,WANG Yazhen,CHEN Chun,WANG Hao. Determination of Residual Monomers in Acrylic Pressure Sensitive Adhesive by HPLC[J]. , 2010, 41(2)
Authors:HU Jing  LUO Huafei  WANG Yazhen  CHEN Chun  WANG Hao
Abstract:An HPLC method was established for the determination of vinyl acetate.ethyl acrylate and n-butyl acrylate,the residual monomers in acrylic pressure sensitive adhesive(PSA).A C_(18) column was used with the mobile phase of acetonitrile-water(40:60)at the detection wavelength of 210 mn.The calibration curves of vinyl acetate,ethyl acrylate and n-butyl acrylate were linear in the concentration ranges of 0.04-20,0.04-20,0.2-1 00 μg/ml.The average recoveries were 99.6%,100.8%and 99.4%,respectively,with RSDs less than 2%.The RSDS of intra-and inter-day were less than 3%and 5%.
Keywords:acrylic pressure sensitive adhesive(acrylic PSA):residual monomers  HPLC  determination
本文献已被 万方数据 等数据库收录!