首页 | 本学科首页   官方微博 | 高级检索  
     


Implantable Cardioverter Defibrillator Therapy for Primary Prevention of Sudden Cardiac Death after Myocardial Infarction:
Authors:PAUL W.X. FOLEY,M.R.C.P.,CLARA E. ADDISON,STEPHANIE B. WHINNEY,KIRAN PATEL,PH.D.,F.R.C.P.,&dagger  ,DAVID CUNNINGHAM,M.D.,F.R.C.P.,&Dagger  ,MICHAEL P. FRENNEAUX,PH.D.,F.R.C.P.,§  , FRANCISCO LEYVA,M.D.,F.R.C.P.
Affiliation:From the University of Birmingham, Good Hope Hospital, Sutton Coldfield, UK;;University of Birmingham, Sandwell and West Birmingham Hospitals NHS Trust, Birmingham, UK;;National Pacemaker and ICD Database, Central Cardiac Audit Database, UK;;and University of Birmingham, Queen Elizabeth Hospital, Birmingham, UK
Abstract:Study Objective: To estimate the proportion of patients eligible for implantable cardioverter defibrillator (ICD) therapy for the primary prevention of sudden cardiac death after a myocardial infarction (MI), according to the current guidelines.
Methods: Eligibility was assessed retrospectively at 6 weeks in 513 post-MI survivors (age 66 ± 13 years, left ventricular ejection fraction 48.2 ± 17%) on the basis of an electrocardiogram and an echocardiogram.
Results: LVEF was ≤ 40% in 37% and ≤ 35% in 30%, and QRS duration was <120 ms in 89% and ≥120 ms in 11% of patients. The proportion of post-MI patients meeting the criteria set by guidelines were 37% for 2006 American College of Cardiology/American Heart Association/European Society of Cardiology (ACC/AHA/ESC) 26.5% for 2008 ACC/AHA/Canadian Heart Rhythm Society 16.3% for 2005 US Centers for Medicare and Medicaid Services (CMS), and 5.8% for the 2006 United Kingdom (UK) National Institute of Clinical Excellence (NICE). According to 2005 CMS and 2006 UK-NICE guidelines, Holter monitoring was required in 7% and 18%, respectively. For the United States (700,000 MI in 2006), the 2006 ACC/AHA/ESC guidelines equate to 216,783 ICD implantations/year. For UK (60,499 MI in 2006), the 2006 NICE guidelines equate to 2,941 ICD implantations, 10,488 Holter studies, and 1,065 VT induction tests/year.
Conclusions: Current ICD therapy guidelines for primary prevention of SCD post-MI demand a substantial increase in service provision worldwide.
Keywords:primary prevention    sudden cardiac death    implantable cardioverter defibrillator    myocardial infarction    ventricular tachyarrhythmia