首页 | 本学科首页   官方微博 | 高级检索  
检索        


Wavelength dependence of the precision of noninvasive optical measurement of oxy-, deoxy-, and total-hemoglobin concentration.
Authors:Y Yamashita  A Maki  H Koizumi
Institution:Hitachi, Ltd., Advanced Research Laboratory, Hatoyama, Saitama, 350-0395, Japan.yu-yama@crl.hitachi.co.jp
Abstract:The precision of noninvasive optical measurement of the concentration changes in oxy-, deoxy-, and total-hemoglobin depends on wavelength. For estimating the precision, we calculated the noise level of the concentration changes as the uncertainty in measurements using several wavelength pairs of light. Seven laser diodes (664-848 nm) were used simultaneously for spectroscopic measurement of brain activity during finger motor stimulation. We also used the analysis of error propagation from the uncertainty in direct measurements of absorbance changes to estimate indirectly the uncertainty of concentration changes. The measurement of the concentration changes made using an 830/664-nm pair are two times (oxy-Hb) and six times (deoxy-Hb) more precise than those made using an 830/782-nm pair.