首页 | 本学科首页   官方微博 | 高级检索  
检索        


Multi-axial correction system in the treatment of radial club hand
Authors:Suneel B Bhat  Atul F Kamath  Kriti Sehgal  B David Horn  Harish S Hosalkar
Institution:1. Division of Pediatric Orthopaedic Surgery, The Children’s Hospital of Philadelphia, 34th Street and Civic Center Boulevard, Philadelphia, PA, 19104, USA
2. University of Pennsylvania School of Medicine, Philadelphia, PA, 19104, USA
3. Department of Orthopaedic Surgery, Hospital of the University of Pennsylvania, 34th and Spruce Streets, 2nd Floor, Silverstein Building, Philadelphia, PA, 19104, USA
4. Department of Orthopaedic Surgery, Rady Children’s Hospital, UCSD, 3030 Children’s Way, Suite 410, San Diego, CA, 92123, USA
Abstract:

Background

Radial club hand is a well-recognized congenital malformation characterized by hypoplasia of bone and soft tissue on the radial aspect of the forearm and hand. The modalities of treatment have traditionally varied from stretching casts with soft-tissue procedures to the use of multiple corrective osteotomies. These osteotomies can be stabilized by a variety of methods, including external fixators that allow the possibility of gradual distraction with neohistiogenesis. This current study outlines the usage of one such device (multi-axial correction system MAC]) in the management of deformity associated with severe radial club hand.

Methods

Three consecutive cases of unilateral or bilateral severe (Bayne type IV) congenital radial club hand were corrected using MAC fixation in the last 5 years. This is a retrospective review of all three cases. Data parameters included: patient demographics, presentation findings, degree of deformity, amount of correction/lengthening, length of procedure, length of treatment, and associated complications. The surgical technique is described in detail for the benefit of the readership.

Results

The three patients with severe congenital radial club hand had a total of four limb involvements that underwent correction using osteotomies and usage of the MAC device for external fixation. All three patients underwent successful correction of deformity with the restoration of alignment, lengthening of forearm for improvement of function, and stabilization of the wrist (mean duration, mean lengthening, mean time to consolidation). The MAC system was well tolerated in all patients and associated complications were limited.

Conclusion

The MAC fixator seems to be a good alternative modality of stabilization and correction for severe congenital radial club hand deformities. Its usage is fairly simple and it provides the ease of application of a mono-lateral fixator with far superior three-dimensional control, like the circular external fixator. We recommend that clinicians should add this modality to their armamentarium for the deformity correction of severe radial club hand and others in general.
Keywords:MAC fixator  Radial club hand  Multi-axial correction system
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号