首页 | 本学科首页   官方微博 | 高级检索  
检索        


Coupling of drug containing liposomes to microbubbles improves ultrasound triggered drug delivery in mice
Authors:Steven K Cool  Bart Geers  Stefan Roels  Stephan Stremersch  Katrien Vanderperren  Jimmy H Saunders  Stefaan C De Smedt  Joseph Demeester  Niek N Sanders
Institution:1. Laboratory for Gene Therapy, Faculty of Veterinary Medicine, Ghent University, Heidestraat 19, 9820 Merelbeke, Belgium;2. Ghent Research Group on Nanomedicines, Laboratory of General Biochemistry and Physical Pharmacy, Faculty of Pharmaceutical Sciences, Ghent University, Harelbekestraat 72, 9000 Ghent, Belgium;3. Service of Orientation and Veterinary Support, Operational Direction of Interactions and Surveillance, Veterinary and Agrochemical Research Centre (CODA-CERVA), Groeselenberg 99, 1180 Brussels, Belgium;4. Department of Veterinary Medical Imaging and Small Animal Orthopaedics, Faculty of Veterinary Medicine, Ghent University, Salisburylaan 133, 9820 Merelbeke, Belgium
Abstract:Local extravasation and triggered drug delivery by use of ultrasound and microbubbles is a promising strategy to target drugs to their sites of action. In the past we have developed drug loaded microbubbles by coupling drug containing liposomes to the surface of microbubbles. Until now the advantages of this drug loading strategy have only been demonstrated in vitro. Therefore, in this paper, microbubbles with indocyanine green (ICG) containing liposomes at their surface or a mixture of ICG-liposomes and microbubbles was injected intravenously in mice. Immediately after injection the left hind leg was exposed to 1 MHz ultrasound and the ICG deposition was monitored 1, 4 and 7 days post-treatment by in vivo fluorescence imaging. In mice that received the ICG-liposome loaded microbubbles the local ICG deposition was, at each time point, about 2-fold higher than in mice that received ICG-liposomes mixed with microbubbles. We also showed that the perforations in the blood vessels allow the passage of ICG-liposomes up to 5 h after microbubble and ultrasound treatment. An increase in tissue temperature to 41 °C was observed in all ultrasound treated mice. However, ultrasound tissue heating was excluded to cause the local ICG deposition. We concluded that coupling of drug containing liposomes to microbubbles may increase ultrasound mediated drug delivery in vivo.
Keywords:Targeted drug delivery  Microbubbles  Liposomes  Ultrasound  In vivo fluorescence imaging
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号