首页 | 本学科首页   官方微博 | 高级检索  
     

经皮肾穿刺活检的超声引导技巧研究(附846例分析)
引用本文:程瑞洪,简 讯,李 斌等.经皮肾穿刺活检的超声引导技巧研究(附846例分析)[J].四川医学,2014(3):290-292.
作者姓名:程瑞洪  简 讯  李 斌等
作者单位:川北医学院附属第二医院·绵阳404医院医学超声科,肾内科,四川绵阳621000
基金项目:四川省卫生厅科研课题(编号:100326)
摘    要:目的探讨经皮肾穿刺活检术的超声引导技巧,提高肾穿刺活检成功率,降低并发症。方法回顾分析我院846例应用自动活检枪在超声实时引导下行肾穿活检患者的临床资料,对肾穿刺针数、穿刺肾别、获取的肾小球数目及并发症的情况进行统计分析。结果846例患者1次2针穿刺成功825例(97.52%),1次3针穿刺成功21例(2.48%);活检肾小球10~20多个;795例(93.97%)行右肾穿刺,其余行左肾穿刺;并发腰痛及腰部不适126例(14.58%),肾周血肿22例(2.60%),一过性肉眼血尿18例(2.12%),无穿刺所致的感染。结论选用自动活检枪切割式穿刺针,超声实时引导、准确定位对提高肾穿活检一次性成功率、降低并发症起决定性作用。

关 键 词:肾穿刺活检  超声引导  技巧

Study on Clinical Skill of Guidance of Utrasonography in Percutaneous Renal Biopsy.
Affiliation:Cheng Ruihong, Jian Xun, Li Bin, et al. The Second Affiliated Hospital of North Sichuan Medical College (Sichuan Mianyang 404 Hospital), Mianyang, Sichuan 621000, China
Abstract:Objective To explore the clinical skill of guidance of utrasonography in percutaneous renal biopsy, improve the successful rate of percutaneous renal biopsy and reduce complications. Methods 846 patients with renal diseases underwent ultrasound-guided percutaneous renal biopsy. The relations between complications rates with the frequency of puncture, biopsied renal status, the amount of renal glomerulus were analyzed. Results 825 samples were successfully performed by 2 needle once, and 21 samples were successfully performed by 3 needle once, the renal glomerulus were more than 10 - 20. 93.97% punctures occured on right renal. The main complications were osphyalgia and lumbar discomfort in 126 cases( 14.58% ) , perirenal hemato- ma in 22 cases (2.60%), and temporal naked eye hematuria in 18 cases (2.12%). Conclusion Selecting the Tru-Cut needle, accurate direction and a suitable puncture point under ultrasound-guided are important in improving the successful rate of first puncture and decreasing the complications of renal biopsy.
Keywords:renal biopsy  utrasound-guided  clinical skill
本文献已被 CNKI 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号