低剂量4DCT扫描在肺内孤立性肿瘤模拟定位与靶区构建中的应用价值
引用本文:尚东平,栾丽娟,王俪臻,孙庆宁,于金明,尹勇.低剂量4DCT扫描在肺内孤立性肿瘤模拟定位与靶区构建中的应用价值[J].中华放射肿瘤学杂志,2022,31(2):165-169.
作者姓名:尚东平  栾丽娟  王俪臻  孙庆宁  于金明  尹勇
作者单位:山东省肿瘤防治研究院(山东省肿瘤医院)放疗科,山东第一医科大学(山东省医学科学院), 济南 250117
基金项目:山东省医药卫生科技发展计划项目(202109030501)。
摘    要:目的:探讨低剂量4DCT扫描在肺内孤立性肿瘤模拟定位和靶区构建中的可行性。方法:23例肺内孤立性肿瘤序贯完成常规条件(CON)、低管电压(LV)、低管电流(LA)、低管电压+低管电流(LVA)条件下4DCT扫描模拟定位,基于各序列图像分别进行靶区构建与配准,比较不同扫描条件下肿瘤内运动靶区(IGTV)体积、位置、肿瘤位...

关 键 词:低剂量  体层摄影术,X线计算机,四维  大体肿瘤体积  肺肿瘤/放射疗法
收稿时间:2021-01-22

Application value of low-dose 4DCT scanning in simulation and target delineation for solitary pulmonary tumors
Shang Dongping,Luan Lijuan,Wang Lizhen,Sun Qingning,Yu Jinming,Yin Yong.Application value of low-dose 4DCT scanning in simulation and target delineation for solitary pulmonary tumors[J].Chinese Journal of Radiation Oncology,2022,31(2):165-169.
Authors:Shang Dongping  Luan Lijuan  Wang Lizhen  Sun Qingning  Yu Jinming  Yin Yong
Institution:Department of Radiation Oncology,Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences,Ji′nan 250117,China
Abstract:Objective To explore the feasibility of low-dose 4DCT scanning in simulation and target delineation for solitary pulmonary tumors(SPTs).Methods 23 patients with SPTs received 4DCT scanning simulation with the conventional scanning(CON),low voltage(LV),low current(LA)and low voltage combined with low current(LVA)in sequence.Based on the 4DCT images derived from the four sets of scanning parameters,the internal gross tumor volume(IGTVCON,IGTVV,IGTVA,IGTVVA)of SPTs were delineated and matched.Taking IGTVCON as reference,the tumor displacement and the centroid position of IGTVV,IGTVA and IGTVVA were compared with IGTVCON.The radiation doses under different scanning parameters were compared.Results The volumes of IGTVCON,IGTVV and IGTVA were(12.26±12.30)cm3,(12.21±12.16)cm3 and(11.87±11.70)cm3,respectively(P=0.337).IGTVVA was(11.34±11.07)cm3,significantly smaller than IGTVCON(P=0.005).There was no significant difference in the centroid positions of IGTVCON,IGTVV,IGTVA and IGTVVA in three directions(P=0.491,0.360,0.136).The Dice′s similarity coefficient(DSCVA)was significantly lower than DSCV and DSCA(P=0.004,0.030).The tumor displacement measured by the four sets of 4DCT images was similar in the LR direction(P=0.470),and also in the AP direction(P=0.108).For the displacement in the SI direction,LVA scanning was smaller than CON(P=0.015).The radiation doses under four different scanning conditions were(397.0±140.3)mGy·cm,(175.0±61.8)mGy·cm,(264.8±95.3)mGy·cm and(116.8±41.2)mGy·cm,respectively(P<0.001).Conclusions LV or LA scanning exert no significant effect on the volume,centroid position of IGTV and the tumor displacement in 4DCT simulation for SPTs.The radiation dose that patients receive under LV and LV scanning is lower than that of CON.Consequently,LV or LA scanning is feasible in 4DCT simulation and target delineation for SPTs.
Keywords:Low dose  Tomography  X-ray computed  four-dimensional  Gross tumor volume  Lung neoplasm/radiotherapy