CT横断序列辅助三维容积测量技术评估房间隔缺损的可行性研究
引用本文:宋会军,刘琼,金敬琳,张旌,李世国,闫朝武,宋宜萤,徐亮,万俊义.CT横断序列辅助三维容积测量技术评估房间隔缺损的可行性研究[J].中华放射学杂志,2022(1):68-73.
作者姓名:宋会军  刘琼  金敬琳  张旌  李世国  闫朝武  宋宜萤  徐亮  万俊义
作者单位:中国医学科学院;中国医学科学院阜外医院深圳医院心脏外科;中国医学科学院
摘    要:目的:探讨CT横断序列辅助三维容积测量(CTAS)技术评估房间隔缺损(ASD)的可行性。方法:回顾性收集2016年1月至2019年12月在阜外医院成功行介入治疗的单发继发孔型ASD患者。患者于封堵前及封堵后第2天均行冠状动脉CT血管成像(CTA)检查,且ASD封堵术中行DSA检查。最终入组52例,其中37例为缺损后下缘...

关 键 词:房间隔缺损  血管造影术  成像,三维  心脏导管插入术  间隔封堵器

Feasibility of three-dimensional CT axial sequence assisted volumetric measurement for atrial septal defect evaluation
Song Huijun,Liu Qiong,Jin Jinglin,Zhang Jing,Li Shiguo,Yan Chaowu,Song Yiying,Xu Liang,Wan Junyi.Feasibility of three-dimensional CT axial sequence assisted volumetric measurement for atrial septal defect evaluation[J].Chinese Journal of Radiology,2022(1):68-73.
Authors:Song Huijun  Liu Qiong  Jin Jinglin  Zhang Jing  Li Shiguo  Yan Chaowu  Song Yiying  Xu Liang  Wan Junyi
Institution:(Center for Structural Heart Disease,Fuwai Hospital,National Center for Cardiovascular Diseases,Chinese Academy of Medical Sciences and Peking Union Medical College,Beijing 100037,China;Department of Cardiac Surgery,Fuwai Hospital,Chinese Academy of Medical Sciences,Shenzhen,Shenzhen 518057,China;Department of Ultrasonography,Fuwai Hospital,National Center for Cardiovascular Diseases,Chinese Academy of Medical Sciences and Peking Union Medical College,Beijing 100037,China)
Abstract:Objective To explore the feasibility of three-dimensional CT axial sequence assisted volumetric measurement(CTAS)in evaluating atrial septal defect(ASD).Methods The patients with single secundum ASD who successfully underwent interventional therapy in Fuwai Hospital from January 2016 to December 2019 were retrospectively collected.The patients underwent coronary CT angiography(CTA)before and on the second day after closures,and DSA examinations during operation.A total of 52 cases met the inclusion conditions,among them,there were 37 patients with large defects which had deficient inferior rims≤3 mm,and 15 patients with severe pulmonary arterial hypertension that occluded with fenestrated ASD occluder.The CT data of patients before and after operation were reconstructed by CTAS.Then the anatomical structure of ASD before the operation was evaluated,including the long diameter and short diameter of ASD,and the CT three-dimensional volume diameter of ASD was calculated by using the equivalent circle conversion formula of ellipse.The waist diameter of occluder and rims of the ASD were measured after occlusion on postoperative CT three-dimensional volume reconstruction images.Meanwhile,the deployed occluder waist dimension was measured in DSA examination during the operation by simulating the balloon measurement of ASD.Lastly,paired t-test and consistency analysis were carried out among the values of parameters.Results Before operation,the equivalent circle diameter of ASD was(32.3±5.4)mm measured by CTAS.After ASD occlusion,the size of the waist dimension measured by DSA and CTAS were(32.5±4.9)mm and(32.6±4.9)mm.There were no significant differences between them(P>0.05).There were also no significant differences for each rims of the ASD pre and post operation on CTAS except for the inferior rims and the total length of atrial septum in superior-inferior direction(P>0.05).Conclusion As an alternative to balloon sizing,CTAS can be used as a reference standard to conduct ASD interventional treatment.
Keywords:Heart septal defects  atrial  Angiography  Imaging  three-dimensional  Cardiac catheterization  Septal occluder device