Abstract:A sensitive high-performance liquid chromatography method with electrochemical detection was developed for the purpose of determining the concentration of the new anti-tumor agent 1-[4-(furo[2,3-b]-quinolin-4-ylamino)phenyl]ethanone (FQPE) in rats. The plasma samples were spiked with the internal standard diclofenac and extracted using dichloromethane. A C(18) 250 mm x 4mm column was used for the separation of analyte with a mobile phase consisting of 50% acetonitrile and 50% pH 3.0 of sodium 1-pentansulfonate solution at a flow rate of 1.0 mL/min. FQPE was detected by electrochemical detector at 1.0 V and 20 nA. Intra-day and inter-day precision and accuracy were acceptable down to the limit of quantization of 1 ng/mL. The lower limit of detection (LOD) was 0.5 ng/mL. The pharmacokinetic parameters of FQPE in rats after intravenous administration of 2.1 and 4.2 mg/kg were determined. The apparent volume of distribution, half-life of elimination, and clearance showed no significant difference between the two dosages. The area under the plasma concentration time curve increased proportionally with dose. The half-life of FQPE was prolonged about 2.4-fold, compared with amsacrine.