首页 | 本学科首页   官方微博 | 高级检索  
检索        

血管内支架置入术治疗Stanford B 型主动脉夹层
引用本文:赵金平,廖永德,高思海,马业新,胡道予.血管内支架置入术治疗Stanford B 型主动脉夹层[J].放射学实践,2006,21(6):600-602.
作者姓名:赵金平  廖永德  高思海  马业新  胡道予
作者单位:430030,武汉,华中科技大学同济医学院附属同济医院胸心外科;430030,武汉,华中科技大学同济医学院附属同济医院心血管内科;430030,武汉,华中科技大学同济医学院附属同济医院放射科
摘    要:目的:总结主动脉血管支架置入术治疗Stanford B型主动脉夹层的临床经验。方法:术前对15例Stanford B型主动脉夹层患者进行主动脉全程薄层增强CT扫描及血管成像,以获得主动脉夹层病变解剖学特征。在局麻下行主动脉造影,并与CT结果比较,选取支架血管型号。全麻下切开左股动脉或右股动脉,置入支架血管,封堵原发破口,重复造影检查有无内漏。术后1周及1年行CT随访,观察有无内漏、支架移位和假腔变化。结果:15例均获临床成功。1例见少量近端内漏,未发生其他并发症。CT随访,5例主动脉夹层消失,余者假腔内血栓形成。结论:与传统手术相比,腔内隔绝术治疗Stanford B型主动脉夹层具有创伤小、并发症少、安全性高等优点,近期疗效满意。

关 键 词:动脉瘤  夹层  支架  放射学  介入性
文章编号:1000-0313(2006)06-0600-03
修稿时间:2005年12月13

Endovascular Aortic Stent-graft Placement for Treatment of Stanford Type B Aortic Dissection:Experience of 15 Cases
ZHAO Jin-ping,LIAO Yong-de,GAO Si-hai,et al..Endovascular Aortic Stent-graft Placement for Treatment of Stanford Type B Aortic Dissection:Experience of 15 Cases[J].Radiologic Practice,2006,21(6):600-602.
Authors:ZHAO Jin-ping  LIAO Yong-de  GAO Si-hai  
Institution:ZHAO Jin-ping,LIAO Yong-de,GAO Si-hai,et al.Department of Cardiothoracic Surgery,Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,Wuhan 430030,P.R.China
Abstract:Objective:To introduce the experience of endovascular stent-graft placement for treatment of 15 cases of Stanford type B aortic dissection. Methods:Contrast-enhanced thin-slice CT was performed preoperatively to obtain the anatomical characteristics of the aortic dissection.Aortography was performed under local anesthesia.The size of the endovascular stent-grafts were chosen according to consensus of aortic CT and aortography.Vascular access was obtained through femoral arteriotomy and stent-graft was placed in the true lumen of the aorta to occlude the primary intimal tear under general anesthesia.Immediate aortography was performed after placement of the stent-graft to demonstrate if there existed any endoleak.Follow-up CT angiography 1 week and 1 year postoperatively was used to evaluate treatment efficacy.Results:Clinical success was achieved in all 15 cases.Immediate aortography revealed minor endoleak in one case,no other complications occurred.Follow-up CT showed that the false lumens disappeared in 5 cases and were filled with thrombus in the other patients.Conclusion:The short- and mid-term efficacy of endovascular stent-graft therapy for Stanford type B aortic dissection is satisfactory with less invasiveness and definite safety.
Keywords:Aneurysm  dissecting  Stents  Radiology  interventional [HJ0] [HJ]
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《放射学实践》浏览原始摘要信息
点击此处可从《放射学实践》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号