多层螺旋CT肝脏增强多期扫描成像质量分析
引用本文:王敏杰,王培军,左长京,李晓兵,萧毅,邵成伟,薛宏. 多层螺旋CT肝脏增强多期扫描成像质量分析[J]. 中国医学影像技术, 2002, 18(5): 417-418
作者姓名:王敏杰  王培军  左长京  李晓兵  萧毅  邵成伟  薛宏
作者单位:第二军医大学长海医院放射科,上海,200433
摘    要:目的 回顾性分析多层螺旋CT肝脏增强多期扫描成像质量,找出影响该图像质量的因素及相关关系。方法 选择我院完成的2456例肝脏增强多期扫描图像,分别对肝动脉期、门脉期进行成像质量评价。结果 当注射速度为3.0ml/s、剂量为1.5ml/kg时,大部分(>70%)病人能在注射开始后23s与45s获得满意的动脉期和门脉期图像。结论 当以上述注射速度和剂量从肘静脉注射非离子型对比剂(300mgI/ml)时,超过70%的病人肝动脉和门静脉对比剂达到峰值的时间分别为26-28s和48-50s。

关 键 词:多层螺旋CT 肝脏增强多期扫描成像 质量分析 肝脏 对比剂
文章编号:1003-3289(2002)05-0417-02
收稿时间:2001-11-15
修稿时间:2001-11-15

Multi-Slice Helical CT : Image Quality Analysis of Hepatic Multiphases Enhancement
WANG Min-jie,WANG Pei-jun,ZUO Chang-jing,LI Xiao-bing,XIAO Yi,SHAO Cheng-wei and XUE Hong. Multi-Slice Helical CT : Image Quality Analysis of Hepatic Multiphases Enhancement[J]. Chinese Journal of Medical Imaging Technology, 2002, 18(5): 417-418
Authors:WANG Min-jie  WANG Pei-jun  ZUO Chang-jing  LI Xiao-bing  XIAO Yi  SHAO Cheng-wei  XUE Hong
Affiliation:Department of Radiology, Changhai Hospital of the Second Military Medical University, Shanghai 200433,China;Department of Radiology, Changhai Hospital of the Second Military Medical University, Shanghai 200433,China;Department of Radiology, Changhai Hospital of the Second Military Medical University, Shanghai 200433,China;Department of Radiology, Changhai Hospital of the Second Military Medical University, Shanghai 200433,China;Department of Radiology, Changhai Hospital of the Second Military Medical University, Shanghai 200433,China;Department of Radiology, Changhai Hospital of the Second Military Medical University, Shanghai 200433,China;Department of Radiology, Changhai Hospital of the Second Military Medical University, Shanghai 200433,China
Abstract:Purpose To evaluate the effective factors of image quality by interpreting the images of hepatic multiphases enhancement retrospectively. Methods All of 2456 cases were performed on multi slice helical CT, and multiphases including arterial and portal phase were acquired. All images of arterial and portal phase were respectively evaluated. Results Most images of arterial and portal phase (>70%) were excellent when scan delay time at 23s and 45s after injection with a 1.5ml/kg bolus of contrast material infused at 3.0ml/s. Conclusion The peak time of arterial and portal phase were 26-28s, 48-50s for most patients with the above mentioned dose and injection rate.
Keywords:Tomography   X ray computed  Liver  Contrast medium