首页 | 本学科首页   官方微博 | 高级检索  
检索        


The long-tube single plate Molteno implant for the treatment of recalcitrant glaucoma
Authors:C E Traverso  K F Tomey  A Al-Kaff
Institution:(1) King Khaled Eye Specialist Hospital, P.O. Box 7191, 11462 Riyadh, Kingdom of Saudi Arabia
Abstract:One hundred cases of recalcitrant glaucoma were operated with a long tube single-plate Molteno implant (LSMI). At the median follow-up of 15 months an intraocular pressure of le19 mm Hg was obtained in 64 of the 87 eyes (73%) which have a minimum follow-up of 6 months (secondary non-neovascular glaucomas=19; congenital glaucomas=26; secondary neovascular glaucomas=12). The interval probability (percentage±standard error) of obtaining a successful result (IOPle19 mmHg) was 79% (±13) at twelve months from surgery, and 53% (±24) at the eighteen month interval. The least favorable results were obtained in the secondary non-neovascular glaucomas. Complications observed included choroidal detachment (24%), tube exposure (4%), tube-endothelium contact (6%), plus band keratopathy, fibrous ingrowth, traction retinal detachment and corneal ulcers.Seventeen cases needed repeate surgery for the management of complications. In order to decrease the post-operative hypotony, we have been using a tourniquet suture around the tube at the time of implantation to occlude it temporarily and limit the outflow.
Keywords:Molteno implant  refractory glaucoma
本文献已被 SpringerLink 等数据库收录!