首页 | 本学科首页   官方微博 | 高级检索  
     


Hepatic resection using the harmonic scalpel
Authors:Hiroyuki Sugo  Youshi Mikami  Fumio Matsumoto  Hidenori Tsumura  Yozo Watanabe  Kuniaki Kojima  Shunji Futagawa
Affiliation:(1) Department of Surgery, Koshigaya Municipal Hospital, 10-47-1 Higashikoshigaya, Koshigaya, Saitama 343-0023, Japan, JP;(2) Second Department of Surgery, Juntendo University, School of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo 113-8421, Japan, JP
Abstract:We describe herein our technique of performing extensive resection of the liver by blunt dissection in combination with excision using a harmonic scalpel. A ball coagulator was inserted at 3-cm intervals along the proposed cutting line in the liver, and the liver parenchyma between these holes was then cut using coagulation shears. Regardless of the condition of the liver, good coagulation and cutting were achieved using the harmonic scalpel without vascular occlusion when dividing the shallow layer of the liver, and no complications in association with the harmonic scalpel, such as postoperative bleeding, bile leakage, or abscess formation at the cut margins, occurred. In the deep layer below the main trunk of the hepatic vein, blunt dissection was used, since it was difficult to achieve sufficient control of bleeding from large vessels using the harmonic scalpel alone. Therefore, when used in combination with other techniques, the harmonic scalpel appears to be an effective device for liver surgery that minimizes bleeding and decreases the vascular clamping time. Received: October 14, 1999 / Accepted: May 30, 2000
Keywords:Liver resection  Harmonic scalpel  Hepatocellular carcinoma
本文献已被 PubMed SpringerLink 等数据库收录!