首页 | 本学科首页   官方微博 | 高级检索  
     

Liquid chromatography electrospray ionization tandem mass spectrometry(LC/ESI-MS/MS) method for quantitative estimation of moxifloxacin in human plasma
引用本文:Vipul.M.Vaghela,Prajesh Prajapati,Hetal K.Patel. Liquid chromatography electrospray ionization tandem mass spectrometry(LC/ESI-MS/MS) method for quantitative estimation of moxifloxacin in human plasma[J]. 中国药学, 2014, 23(3): 159-164. DOI: 10.5246/jcps.2014.03.020
作者姓名:Vipul.M.Vaghela  Prajesh Prajapati  Hetal K.Patel
作者单位:[1]Shree Swaminarayan Sanskar Pharmacy College, Zundal-382 421, Gujarat, India [2]A. R. College of Pharmacy and G. H. Patel Institute of Pharmacy, Vallabh Vidhyanagar-388120, Gujarat, lndia [3]Institute of Research and Development, Gujarat Forensic Sciences University, Gandhinagar-382007, Gujarat, India
基金项目:Acknowledgements The authors are thankful to the Zydus Cadila Healthcare Ltd, Ahmedabad, for providing necessary facilities to carry out this work and all the materials for development.
摘    要:A rapid and sensitive liquid chromatography tandem mass spectrometry(LC-MS/MS) method has been developed and validated for the determination of moxifloxacin(MOXI) in human plasma. After a simple protein precipitation using acetonitrile, the post treatment samples were analysed on a C18 column interfaced with a Triple Quadropole Tandem Mass Spectrometer. Positive electrospray ionization was employed as the ionization source. The mobile phase consisted of 0.1% formic acid–acetonitrile(60:40, v/v). Ciprofloxacin(CIPRO) was used as an internal standard. The analyte and internal standard(CIPRO) were monitored in the multiple reaction monitoring mode(MRM). The mass transition ion-pair has been followed as m/z 402→358.2 for MOXI and 332→288.1 for CIPRO. The method was linear in the concentration range of 25–5000 ng/mL. The lower limit of quantification was 25 ng/mL. The intra- and inter-day precision(relative standard deviation) and accuracy(relative error) values were within 12.4%. Each plasma sample was analyzed within 3 min.

关 键 词:Moxifloxacin  Ciprofloxacin  Human plasma  Liquid chromatography tandem mass spectrometry  Electrospray ionization
收稿时间:2013-10-07

Liquid chromatography electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method for quantitative estimation of moxifloxacin in human plasma
Vipul. M. Vaghela,Prajesh Prajapati,Hetal K. Patel. Liquid chromatography electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method for quantitative estimation of moxifloxacin in human plasma[J]. Journal of Chinese Pharmaceutical Sciences, 2014, 23(3): 159-164. DOI: 10.5246/jcps.2014.03.020
Authors:Vipul. M. Vaghela  Prajesh Prajapati  Hetal K. Patel
Abstract:A rapid and sensitive liquid chromatography tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the determination of moxifloxacin (MOXI) in human plasma. After a simple protein precipitation using acetonitrile, the post treatment samples were analysed on a C18 column interfaced with a Triple Quadropole Tandem Mass Spectrometer. Positive electrosprayionization was employed as the ionization source. The mobile phase consisted of 0.1% formic acid–acetonitrile (60:40, v/v). Ciprofloxacin (CIPRO) was used as an internal standard. The analyte and internal standard (CIPRO) were monitored in the multiple reaction monitoring mode (MRM). The mass transition ion-pair has been followed as m/z 402→358.2 for MOXI and 332→288.1 for CIPRO. The method was linear in the concentration range of 25–5000 ng/mL. The lower limit of quantification was 25 ng/mL. The intra- and inter-day precision (relative standard deviation) and accuracy (relative error) values were within 12.4%. Each plasma sample was analyzed within 3 min.
Keywords:Moxifloxacin  Ciprofloxacin  Human plasma  Liquid chromatography tandem mass spectrometry  Electrospray ionization  
本文献已被 维普 等数据库收录!
点击此处可从《中国药学》浏览原始摘要信息
点击此处可从《中国药学》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏