首页 | 本学科首页   官方微博 | 高级检索  
     


The spring-back phenomenon: does the final position of the nipple areola complex correspond to the pre-operative markings in reduction mammoplasty?
Authors:Yvette Godwin  Maria del Pilar Schneider
Affiliation:(1) City Hospital Nottingham, Nottingham, UK;(2) Northern General Hospital, Sheffield, UK;(3) Department of Animal Breeding and Genetics, Swedish University of Agricultural Sciences, P.O. box 7023-S-75007, Uppsala, Sweden;(4) Flat 3F1, 4 Boroughloch Square, Edinburgh, EH8 9NJ, UK
Abstract:This study investigates whether tissue recoil or patient intrinsic factors influence the final position of the nipple areola complex (NAC) after reduction mammoplasty. The age, pre-operative ptosis, BMI and weight of the tissue resected were recorded as patient intrinsic factors in 37 patients undergoing reduction mammoplasty. The “spring-back” value was defined as the distance from the sternal notch to a nipple landmark on the breast meridian with the patient sitting up, minus the same measurement repeated with the patient recumbent to eliminate the pull of gravity on the breast. Spring back was measured pre-operatively for the nipple and nipple mark then post-operative for the nipple. The difference in centimeters between the final post-operative distance from the sternal notch to the nipple and the level intended by the pre-operative nipple mark was termed the “judgment error.” The final position of the post-operative nipple and the judgment error was compared to the spring-back values and patient intrinsic factors. Pre-operative ptosis was statistically related to increasing patient BMI and mass of tissue resected per breast. Pre-operative spring-back values for the nipple increased with increasing ptosis, BMI and decreasing age. Spring-back values were greater in the lower pole of the breast than in the upper pole. The final position of the nipple was higher than the pre-operative mark in 65% of cases, lower in 8% and as marked in 27% of cases. The post-operative NAC was, on average, 0.6 cm higher than planned pre-operatively. The post-operative distance from the sternal notch to the nipple increased with increasing pre-operative ptosis, mass of breast tissue resected per breast and all three spring-back values. The difference between the level of the pre-operative mark and the final nipple position showed a weak correlation with post-operative spring-back values. The parameters of ptosis, BMI, weight of tissue resected per breast and pre-operative nipple spring back reflect body habitus and breast size. Spring-back values vary between the upper and lower pole of the breast. The final NAC position was higher than that intended at pre-operative marking in the majority of cases. The surgeon instinctively marks the nipple lower in patients with greater pre-operative ptosis and in whom a larger resection is anticipated. Judgment error did not relate to intrinsic factors nor to pre-operative spring-back values; hence, these parameters cannot be applied as predictive tools for more accurate pre-operative marking of the nipple position. This study suggests that the pre-operative nipple mark should be placed, with the patient sitting up, at least 23 cm from the sternal notch and 0.6 cm lower than the final position estimated using the inframammary crease as a landmark. An invited commentary on this paper is available at .
Keywords:Pre-operative markings  Reduction mammoplasy
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号