首页 | 本学科首页   官方微博 | 高级检索  
     

定量组织速度成像技术评价PTCA支架置入后心肌功能改变的研究
引用本文:庄磊,王新房,谢明星,王瑶,费洪文,杨颖,黄润青,王静,卢晓芳,杨亚莉. 定量组织速度成像技术评价PTCA支架置入后心肌功能改变的研究[J]. 中国医学影像技术, 2004, 20(7): 1054-1056
作者姓名:庄磊  王新房  谢明星  王瑶  费洪文  杨颖  黄润青  王静  卢晓芳  杨亚莉
作者单位:华中科技大学同济医学院附属协和医院超声科,湖北,武汉,430022
摘    要:目的探讨超声定量组织速度成像(QTVI)技术评价冠心病患者PTCA支架置入前后局部心肌运动速度的临床应用价值.方法研究对象包括因冠状动脉左前降支(LAD)狭窄接受PTCA支架置入治疗的冠心病患者27例,分别于治疗前1天、治疗后1周及1个月测量左前降支供血区各节段心肌收缩期峰值速度(PSMV)、舒张早期峰值速度(PDMV).另外测量20例正常人左前降支供血区各节段心肌收缩期峰值速度(PSMV)、舒张早期峰值速度(PDMV)作为对照.结果①与正常对照组比较,冠心病组治疗前1天左前降支供血区各节段心肌PSMV、PDMV明显减低(心尖段除外);治疗后1个月室壁运动速度减低节段除前壁中段及前间隔中段 PSMV及PDMV达到正常值,其余节段仍低于正常对照组;②冠心病组治疗前后比较:上述速度减低节段治疗后1周, PSMV及PDMV明显增快;治疗后1个月继续增快.结论 QTVI技术能定量分析PTCA支架置入治疗前后左室壁局部心肌运动速度的变化.

关 键 词:定量组织速度成像  心室功能,左  血管成形术,经腔,经皮冠状动脉  支架
文章编号:1003-3289(2004)07-1054-03
修稿时间:2004-04-13

Assessment of regional wall motion with quantitative tissue velocity imagingafter PTCA and intracoronary stent implantation
ZHUANG Lei,WANG Xin-fang,XIE Ming-xing,WANG Yao,FEI Hong-wen,YANG Ying,HUANG Run-qing,WANG Jing,LU Xiao-fang and YANG Ya-li. Assessment of regional wall motion with quantitative tissue velocity imagingafter PTCA and intracoronary stent implantation[J]. Chinese Journal of Medical Imaging Technology, 2004, 20(7): 1054-1056
Authors:ZHUANG Lei  WANG Xin-fang  XIE Ming-xing  WANG Yao  FEI Hong-wen  YANG Ying  HUANG Run-qing  WANG Jing  LU Xiao-fang  YANG Ya-li
Affiliation:Department of Ultrasound, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China;Department of Ultrasound, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China;Department of Ultrasound, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China;Department of Ultrasound, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China;Department of Ultrasound, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China;Department of Ultrasound, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China;Department of Ultrasound, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China;Department of Ultrasound, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China;Department of Ultrasound, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China;Department of Ultrasound, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
Abstract:
Keywords:Quantitative tissue velocity imaging  Ventricular function   left  Angioplasty   transluminal   percutaneous coronary  Stent
本文献已被 CNKI 维普 万方数据 等数据库收录!