首页 | 本学科首页   官方微博 | 高级检索  
     

利用近红外光谱法测定洛伐他汀胶囊的含量
引用本文:郄冰冰,王润彪,郭毅. 利用近红外光谱法测定洛伐他汀胶囊的含量[J]. 中国药事, 2011, 25(7): 698-699
作者姓名:郄冰冰  王润彪  郭毅
作者单位:河北省药品检验所,石家庄,050011
摘    要:目的利用近红外光谱法测定洛伐他汀胶囊含量。方法采集洛伐他汀胶囊NIR光谱,采用偏最小二乘法(PLS)进行回归,通过建立洛伐他汀胶囊NIR光谱与HPLC法测定值之间的多元校正模型,测定洛伐他汀胶囊的含量。结果定量模型的外部验证决定系数R2为95.8,外部验证均方差(RMSEP)为0.457,内部交叉验证均方差(RMSECV)为0.542。结论本方法快速、简便、无损,结果准确,适用于药品的现场快检。

关 键 词:洛伐他汀胶囊  NIR  偏最小二乘法(PLS)

Determination of Lovastatin Capsules by NIR
Qie Bingbing,Wang Runbiao,Guo Yi. Determination of Lovastatin Capsules by NIR[J]. Chinese Pharmaceutical Affairs, 2011, 25(7): 698-699
Authors:Qie Bingbing  Wang Runbiao  Guo Yi
Affiliation:Qie Bingbing,Wang Runbiao and Guo Yi(The Drug Control Institute of Hebei,Shijiazhuang 050011)
Abstract:Objective To develop a novel method for fast determination of Lovastatin Capsules with NIR.Methods NIR diffuse reflectance spectra of the capsules were collected.Partial least square(PLS) was utilized to build the quantitative models with these spectra using HPLC as a reference method for determination of Lovastatin Capsules.Results The determination coefficients R2 was 95.8 as indicated from the Test Set Validation.RMSEP was 0.457.RMSECV obtained from the validation was 0.542.Conclusion The method is simpl...
Keywords:Lovastatin Capsules  NIR  Partial least square(PLS)  
本文献已被 CNKI 维普 万方数据 等数据库收录!