首页 | 本学科首页   官方微博 | 高级检索  
检索        


Validity and reliability of fatigue severity scale in stroke
Authors:Ozden Ozyemisci-Taskiran  Elif Balevi Batur  Selcen Yuksel  Mustafa Cengiz  Gulcin Kaymak Karatas
Institution:1. Department of Physical Medicine and Rehabilitation, Koc University School of Medicine, Istanbul, Turkey;2. Physical Medicine and Rehabilitation Unit, Ke?i?ren training and Research Hospital, Ankara, Turkey;3. Faculty of Medicine, Department of Biostatistics, Yildirim Beyazit University, Ankara, Turkey;4. Physical Medicine and Rehabilitation Unit, Sirnak State Hospital, Sirnak, Turkey;5. Faculty of Medicine, Department of Physical Medicine and Rehabilitation, Gazi University, Ankara, Turkey
Abstract:Background: Fatigue is a frequent complaint after stroke and may be associated with dependence in activities of daily living, decreased quality of life, increased institutionalization and mortality. Although fatigue severity scale (FSS) is the most frequently used scale in stroke, validation studies are scarce.

Objectives: This study aimed to examine the psychometric properties of FSS in subjects with stroke.

Methods: A total of 46 subjects with stroke who were admitted for rehabilitation and 52 control subjects who were admitted for local musculoskeletal problems were included. A comprehensive assessment including functional independence measure, Folstein Mini-Mental State Examination, Hospital Anxiety and Depression Scale (HADS), visual analog scale for fatigue (VAS), FSS, and vitality subscale of 36-item Medical Outcomes Study Short-Form Health Survey (SF-36v) was conducted. FSS, VAS and SF-36v were repeated 7 days later.

Results: FSS demonstrated excellent internal consistency in subjects with stroke (Cronbach’s alpha: 0.928). There was a moderate correlation between FSS and SF-36v (r = ?0.498, p < 0.001). FSS was weakly correlated with HADS anxiety (r = 0.310, p = 0.041) and HADS depression (r = 0.334, p = 0.027). Test-retest reliability of SF-36v (ICC: 0. 746, CI: 0.518–0.866), VAS (ICC: 0.829, CI: 0.671–0.911) and FSS (ICC: 0.742, CI: 0.512–0.863, p < 0.001) was good. ICC values for individual items of FSS were good except for item 6.

Conclusions: FSS is a valid and reliable scale to measure fatigue in stroke. FSS is not sensitive to differentiate fatigue in stroke from the control subjects with orthopedic problems with similar age and gender.

Keywords:Stroke  fatigue  psychometrics  mental fatigue  patient reported outcome measures  reliability and validity  test-retest reliability
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号