首页 | 本学科首页   官方微博 | 高级检索  
     


FDG-positron emission tomography (PET) has a role to play in the diagnosis and therapy of infective endocarditis and cardiac device infection
Authors:B. Cherie Millar  Bernard D. Prendergast  Abass Alavi  John E. Moore
Affiliation:1. Northern Ireland Public Health Laboratory, Department of Bacteriology, Belfast City Hospital, Lisburn Road, Belfast, BT9 7AD, Northern Ireland, UK;2. Department of Cardiology, The John Radcliffe Hospital, Headington, Oxford, UK;3. Division of Nuclear Medicine, Department of Radiology, University of Pennsylvania School of Medicine, Hospital of the University of Pennsylvania, 3400 Spruce Street, 117 Donner, Philadelphia, PA 19104, USA
Abstract:In recent years, molecular imaging with positron emission tomography (PET) and more recently, PET coupled with computed tomography (CT) have made a valuable impact in various clinical arenas, primarily within the field of oncology, but also in cardiovascular medicine, particularly in detecting coronary artery disease and myocardial viability. More recently, PET imaging has been proven useful in the diagnosis and evaluation of inflammation and infection at different organ sites. Application of PET in the case of Infective Endocarditis (IE) is still in its infancy and indeed the value of this application in the detection of vegetations is debated primarily due to sensitivity issues of the tracer in cardiac tissue and small vegetations. Interestingly, however, reports are now emerging highlighting the role that this application has played in the diagnosis, assessment of complications such as emboli and metastatic infection and the monitoring of therapeutic treatment of IE. More recently, PET/CT has proven valuable in the diagnosis and assessment of cardiac implantable electronic device (CIED)-related infection and its use has highlighted the contribution that this imaging modality may play in assessing the need for surgery in patients with such infections. This article reviews the literature with regard to the potential value of 2-deoxy-2-[18F]fluoro-D-glucose (18FDG)-PET, as well as the pitfalls and limitations of this imaging modality, in relation to cardiac infection. The emerging role 18FDG-PET/CT has in the diagnosis and monitoring of IE, particularly prosthetic valve IE and CIED-related infections should be considered, particularly in difficult cases.
Keywords:Cardiac device   Culture-negative   Infective endocarditis   Pacemaker   Positron emission tomography (PET)   Infection
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号