首页 | 本学科首页   官方微博 | 高级检索  
检索        


Distal protection device aggravated microvascular obstruction evaluated by cardiac MR after primary percutaneous intervention for ST-elevation myocardial infarction
Authors:Chang-Hwan Yoon  Woo-Young Chung  Jung-Won Suh  Young-Suk Cho  Tae-Jin Youn  Eun-Ju Chun  Sang-Il Choi  In-Ho Chae  Dong-Ju Choi
Institution:1. Division of Cardiology, Department of Internal Medicine, Seoul National University Bundang Hospital, Republic of Korea;2. Division of Cardiology, Department of Internal Medicine, Seoul National University Boramae Hospital, Republic of Korea;3. Department of Radiology, Seoul National University Bundang Hospital, Republic of Korea
Abstract:

Background

Protection of distal embolization by balloon occlusion and thrombus aspiration has not improved microvascular circulation nor decreased myocardial injury during primary percutaneous intervention (PCI) for ST-elevation myocardial infarction (STEMI) in randomized trials. In a prospective randomized trial, we investigated the mechanism of the poor effect of distal protection and thrombus aspiration (DP–TA) in 126 patients with STEMI.

Methods

Patients with first-diagnosed STEMI were randomly assigned to DP–TA pretreatment or conventional PCI (c-PCI). Primary endpoint was reduced left ventricular end-diastolic volume (LVEDV) measured by MRI at post-PCI and 6 months after PCI. Secondary end points were infarct ratio (infarct size to entire LV size) by delayed enhancement (DE), area at risk (AAR) ratio (AAR to entire LV size) by T2 high signal, microvascular occlusion index (MVO) ratio (MVO to entire LV size) by DE, and myocardial salvage index (MSI: (AAR − infarct size) ∗ 100 / AAR) using cardiac magnetic resonance imaging (MRI) within 3 days after PCI.

Results

Baseline characteristics of the patients including cardiovascular risk factors and lesion characteristics were similar between the two groups. DT–PA failed to improve LV remodeling at 6 months (LVEDV 140 ± 39 vs 133 ± 37 in c-PCI group, p = 0.418). Infarct ratio, AAR ratio and MSI were not statistically different between DP–TA group and c-PCI group. However, MVO ratio was significantly larger in DP–TA group than in c-PCI group (2.4 ± 2.7 vs 1.1 ± 1.9, p = 0.045).

Conclusion

DP–TA was potentially hazardous in primary PCI for STEMI by increasing MVO. DP–TA should not be used in STEMI.
Keywords:Distal protection device  Primary PCI  STEMI  Coronary microvascular function  Magnetic resonance imaging
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号