Transcatheter Closure of Abnormal Vessels and Arteriovenous Fistulas With the Amplatzer Vascular Plug 4 in Patients With Congenital Heart Disease
Authors:Gesa Wiegand  Ludger Sieverding  Wolfgang Bocksch  Michael Hofbeck
Institution:1. Department of Pediatric Cardiology, University Children’s Hospital, Hoppe-Seyler-Strasse 1, 72076, Tuebingen, Germany
2. Department of Cardiology and Cardiovascular Medicine, University Clinic of Tuebingen, Tuebingen, Germany
Abstract:Although vascular plugs allow the interventional closure of medium-sized to large abnormal vessels, their application is limited by the need for long sheaths or large guiding catheters. The authors report their experience with the new Amplatzer vascular plug 4 (AVP 4), a self-expanding spindle-shaped occluder made of Nitinol wire mash, which can be placed through 4-Fr catheters with an internal diameter of 0.038 in. or larger. From October 2009 until June 2012, 14 AVP 4 devices were deployed in 12 patients (ages, 0.3–48.8 years). Nine patients had venovenous or arteriovenous collaterals in functional univentricular hearts. One patient had pulmonary atresia with a ventricular septal defect and major aortopulmonary collateral arteries, and one patient had a pulmonary arteriovenous fistula. One child had a large coronary artery fistula to the right atrium. The authors used AVP 4 devices with diameters of 4–8 mm. In all the patients, the AVP 4 was implanted successfully. No occluder dislocations and no complications related to the procedure occurred. Complete vessel occlusion was achieved in seven cases. In seven additional cases, a residual shunt was present at the end of the procedure while the patients were still fully heparinized. In 2 of 14 vessels, the decision was made to place additional devices to abolish residual shunting. According to the authors’ experience, the AVP 4 allows safe and effective occlusion of medium-size and large abnormal vessels. It is also well suited for tortuous high-flow vessels such as coronary or pulmonary arteriovenous fistulas. In case of a suboptimal position, it is possible to reposition the occluder with ease. Further studies are needed to determine whether initial residual shunting in heparinized patients disappears during follow-up care. The AVP 4 represents a valuable new device for the interventional treatment of complex congenital vessel malformations.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号