首页 | 本学科首页   官方微博 | 高级检索  
检索        

双源CT心肌灌注碘成像与核素心肌灌注显像诊断犬急性心肌梗死的研究
引用本文:彭晋,张龙江,朱飞鹏,陈思敏,罗松,吉衡山,周长圣,朱虹,卢光明.双源CT心肌灌注碘成像与核素心肌灌注显像诊断犬急性心肌梗死的研究[J].中华放射学杂志,2011,45(2):128-132.
作者姓名:彭晋  张龙江  朱飞鹏  陈思敏  罗松  吉衡山  周长圣  朱虹  卢光明
作者单位:1. 解放军第一七四医院医学影像科,361003
2. 南京军区南京总医院医学影像科,210002
3. 南京军区南京总医院医学核医学科,210002
摘    要:目的 评价双源CT(DSCT)心肌灌注碘成像诊断犬实验性急性心肌梗死的可行性和准确性.方法 6只犬开胸结扎冠状动脉左前降支(LAD)建立心肌梗死模型,另3只仅开胸而不结扎LAD作为对照组,分别于术前及术后3 h行DSCT心肌灌注碘成像扫描,然后行99Tcm-甲氧基异丁异腈(MIBI)SPECT静息态心肌灌注检查.检查结...

关 键 词:心肌梗死  体层摄影术  X线计算机  灌流  体层摄影术  发射型计算机  单光子

Detection of myocardial infarction with dual energy CT myocardial iodine maps and perfusion myocardial single photon emission computed tomography scintigraphy: an experimental study in canine
PENG Jin,ZHANG Long-jiang,ZHU Fei-peng,CHEN Si-min,LUO Song,JI Heng-shan,ZHOU Chang-sheng,ZHU Hong,LU Guang-ming.Detection of myocardial infarction with dual energy CT myocardial iodine maps and perfusion myocardial single photon emission computed tomography scintigraphy: an experimental study in canine[J].Chinese Journal of Radiology,2011,45(2):128-132.
Authors:PENG Jin  ZHANG Long-jiang  ZHU Fei-peng  CHEN Si-min  LUO Song  JI Heng-shan  ZHOU Chang-sheng  ZHU Hong  LU Guang-ming
Abstract:Objective To investigate the feasibility and accuracy of dual energy CT myocardial iodine maps in detecting acute myocardial infarction in canine model. Methods Myocardial ischemia model was made by ligaturing left anterior descending coronary arteries (LAD) after thoracotomy in six dogs, while another 3 dogs undergoing thoracotomy not ligaturing LAD as control group. Before and three hours after operation, dual-source CT (DSCT) was performed, followed by resting 99Tcm-MIBI single photon emission computed tomography myocardial perfusion imaging. Then, dogs were sacrificed, and the hearts were removed, triphenyltetrazolium chloride staining and conventional HE staining were performed. CT number of non-ischemic and ischemic regions were measured and analyzed. The wall of the left ventricle in the short axis was divided into 17 segments, the segments of myocardial perfusion defect in DSCT myocardial iodine maps, SPECT, and pathology were determined. Student t test was used to analyze the difference of CT number between infarcted and non-infarcted myocardium. Kappa test was used for the accuracy of DSCT myocardial iodine maps and SPECT in detecting myocardial ischemia according to the pathological results. Results No abnormal regions were detected using DSCT myocardial iodine maps in preoperative control and infarction group. After thoracotomy, partial sparse or defective perfusion was consistently noted in six dogs' apical anterior and partition wall in both DSCT myocardial iodine maps and SPECT. In the infarcted group, the attenuation of infarction region (34.75 ± 16.66) HU was significantly decreased compared with preoperative measurements ( 123. 18 ± 15.38 ) HU ( t = 10. 526, P < 0. 01 ); decreased perfusion in the infarcted region was also noted in the DSCT myocardial iodine maps and SPECT. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of DSCT myocardial iodine maps and SPECT were 85.0% (34/40) , 84. 1% (95/113) ,65.4% (34/52) ,94. 0%(95/101) ,and 82. 5% (33/40), 90. 3% ( 102/113 ) ,75.0% (33/44) ,93.6% ( 102/109 ), respectively.Kappa values were 0. 63 and 0. 71 for the agreement of DSCT myocardial iodine maps and SPECT.Conclusion DSCT myocardial iodine maps is comparable diagnostic accuracy with rest SPECT myocardial perfusion imaging in detection of acute myocardial infarction in a canine model.
Keywords:Myocardial infarction  Tomography  X-ray computed  Perfusion  Tomography  emission-computed  single-photon
本文献已被 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏