Cardiac magnetic resonance imaging study for quantification of infarct size comparing directly serial versus single time-point measurements of cardiac troponin T. |
| |
Authors: | Evangelos Giannitsis Henning Steen Kerstin Kurz Boris Ivandic Anke C Simon Simon Futterer Christian Schild Peter Isfort Allan S Jaffe Hugo A Katus |
| |
Affiliation: | Abteilung Innere Medizin III, Medizinische Klinik, Universit?tsklinikum Heidelberg, Heidelberg, Germany. |
| |
Abstract: | OBJECTIVES: We compared single-point cardiac troponin T (cTnT) measurements with parameters from serial sampling during 96 h after acute myocardial infarction with magnetic resonance imaging measured infarct mass. BACKGROUND: Contrast-enhanced magnetic resonance imaging (CE-MRI) allows exact quantification of myocardial infarct size. Clinically, measurement of cardiac biomarkers is a more convenient alternative. METHODS: The CE-MRI infarct mass was determined 4 days after primary percutaneous coronary intervention in 31 ST-segment elevation myocardial infarction (STEMI) and 30 non-ST-segment elevation myocardial infarction (NSTEMI) patients. All single-point, peak, and integrated area under the curve (AUC) cTnT values were plotted against CE-MRI infarct mass. RESULTS: All single-point and serial cTnT values were significantly higher in STEMI than in NSTEMI (p < 0.01) patients. Except for the admission values, all single-point values on any of the first 4 days, peak cTnT and AUC cTnT were found to correlate comparably well with infarct mass. Among single-point measurements, cTnT on day 4 (cTnTD4) showed highest correlation and performed as well as peak cTnT or AUC cTnT (r = 0.66 vs. r = 0.65 vs. r = 0.69). Receiver-operator characteristic analysis demonstrated that cTnTD4 >0.84 microg/l predicted infarct mass above median as well as peak cTnT >1.57 microg/l or AUC cTnT (receiver-operator characteristic for AUC: 0.839 vs. 0.866 vs. 0.893). However, estimation of infarct mass with cTnTD4, peak cTnT, and AUC cTnT was worse in patients with NSTEMI (r = 0.36, r = 0.5, r = 0.36) than in STEMI (r = 0.75 vs. r = 0.65 vs. r = 0.76). CONCLUSIONS: All single-point cTnTs, except on admission, give a good estimation of infarct size and perform as well as peak cTnT or AUC cTnT. Infarct estimation by single-point measurements, particularly cTnTD4, may gain clinical acceptance because the measurement is easy and inexpensive. |
| |
Keywords: | |
|
|