首页 | 本学科首页   官方微博 | 高级检索  
     


Combined Use of Texture Features and Morphological Classification Based on Dynamic Contrast-enhanced MR Imaging: Differentiating Benign and Malignant Breast Masses with High Negative Predictive Value
Authors:Shigeharu Ohyu  Mitsuhiro Tozaki  Michiro Sasaki  Hisae Chiba  Qilin Xiao  Yasuko Fujisawa  Yoshiaki Sagara
Affiliation:1.Research and Development Center, Canon Medical Systems Corporation, Ohtawara, Tochigi, Japan;2.Department of Radiology, Sagara Hospital, Kagoshima, Kagoshima, Japan;3.Department of Radiology, Sagara Perth Avenue Clinic, Kagoshima, Kagoshima, Japan;4.MRI Sales Department, Canon Medical Systems Corporation, Kawasaki, Kanagawa, Japan;5.Research & Development Center, Canon Medical Systems (China) Co., Ltd, Beijing, China
Abstract:Purpose: We evaluated the diagnostic performance of the texture features of dynamic contrast-enhanced (DCE) MRI for breast cancer diagnosis in which the discriminator was optimized, so that the specificity was maximized via the restriction of the negative predictive value (NPV) to greater than 98%.Methods: Histologically proven benign and malignant mass lesions of DCE MRI were enrolled retrospectively. Training and testing sets consist of 166 masses (49 benign, 117 malignant) and 50 masses (15 benign, 35 malignant), respectively. Lesions were classified via MRI review by a radiologist into 4 shape types: smooth (S-type, 34 masses in training set and 8 masses in testing set), irregular without rim-enhancement (I-type, 60 in training and 14 in testing), irregular with rim-enhancement (R-type, 56 in training and 22 in testing), and spicula (16 in training and 6 in testing). Spicula were immediately classified as malignant. For the remaining masses, 298 texture features were calculated using a parametric map of DCE MRI in 3D mass regions. Masses were classified into malignant or benign using two thresholds on a feature pair. On the training set, several feature pairs and their thresholds were selected and optimized for each mass shape type to maximize specificity with the restriction of NPV > 98%. NPV and specificity were computed using the testing set by comparison with histopathologic results and averaged on the selected feature pairs.Results: In the training set, 27, 12, and 15 texture feature pairs are selected for S-type, I-type, and R-type masses, respectively, and thresholds are determined. In the testing set, average NPV and specificity using the selected texture features were 99.0% and 45.2%, respectively, compared to the NPV (85.7%) and specificity (40.0%) in visually assessed MRI category-based diagnosis.Conclusion: We, therefore, suggest that the NPV of our texture-based features method described performs similarly to or greater than the NPV of the MRI category-based diagnosis.
Keywords:breast cancer   magnetic resonance imaging   benign mass   texture feature   diagnostic performance
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号