首页 | 本学科首页   官方微博 | 高级检索  
检索        


Quantitation of change in the medullary compartment in renal allograft by ultrasound
Authors:Dominic S C Raj  Ravi Hoisala  Surjit Somiah  S D Sheeba  Maria Yeung
Abstract:Twenty-three renal allograft recipients with uncomplicated post-transplant courses were sonographically evaluated on the 3rd, 10th, 30th, and 90th postoperative day. The cortical thickness (CT), pyramidal length (PL), pyramidal width (PW), corticomedullary ratio (CMR), and medullary pyramidal index (MPI) were determined at each examination. The measurements obtained from the donor before implantation were used as the baseline. PW increased significantly in the absence of rejection and obstruction in renal allograft during the early post-transplant period. Although the MPI, and to a lesser extent the CMR, detected changes in dimensions of the medullary compartment, there was considerable intra- and inter-individual variation in their values during the post-operative period. © 1997 John Wiley & Sons, Inc. J Clin Ultrasound 25:265–269, 1997
Keywords:corticomedullary ratio  medullary pyramidal index  renal transplanation
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号