电话远程胎儿监护系统的临床应用
作者姓名:Pan J  Ye M  Du X
作者单位:潘俊峰(北京铁路总医院妇产科 100038)
摘    要:目的 评价电话远程胎儿监护系统的临床应用价值,探索孕妇家庭自我监护的新途径。方法将204例妊娠合并贫血、糖尿病、溶血、肾脏疾病、胎儿宫内发育迟缓、妊高征的孕妇、分为试验组(97例)和对照组(107例)。试验组以是锭程胎儿监护系统结合胎动计数进行自我

关 键 词:胎儿监护  电话  远程监护系统
修稿时间:1999-05-04

Clinical experience of long-distance electronic fetal heart rate monitoring system by telephone
Pan J,Ye M,Du X.Clinical experience of long-distance electronic fetal heart rate monitoring system by telephone[J].Chinese Journal of Obstetrics and Gynecology,2000,35(1):14-16.
Authors:Pan J  Ye M  Du X
Institution:PAN Junfeng (Department of Obstetrics and Gynecology, Beijing General Railway Hospital, Beijing 100038, China) YE Meimei (Department of Obstetrics and Gynecology, Beijing General Railway Hospital, Beijing 100038, China) DU Xiaoyan (Department of Obstetrics and Gynecology, Beijing General Railway Hospital, Beijing 100038, China)
Abstract:Objective To explore the value of the long distance electronic fetal heart rate monitoring system by telephone and explore a new way of self monitoring at home for pregnant woman. Method 204 high risk pregnant women came to our clinic were enrolled in this study. Complications included pregnancy induced hypertension (PIH), intrauterine growth retardation (IUGR), anemia, diabetes, hemolysis, nephropathy. In the study group, 97 women took the terminal part of the fetal heart rate monitoring system home and were requested to auscultate and count fetal heart rate three times a day, while another 107 cases did the self monitoring by fetal movement counting daily and served as control group. For the study group, whenever woman felt any abnormality of her baby, she could contact the long distance electronic fetal heart rate (FHR) monitoring center in hospital by telephone immediately. The signal of fetal heart beat and fetal movement was converted and analyzed in the electronic FHR monitoring center by computer at the same time. The fetal heart rate curve was printed out, and diagnosis and management could be made. Age, gestational weeks, high risk factors, abnormal non stress test (NST), Apgar score and birth weight of newborn were analyzed between the experimental and control group retrospectively. Results There were no obviously differences in age, gestational weeks, weight of newborn, high risk factors between the 2 groups. The incidence of abnormal NST and Apgar score of newborn were significantly higher in the study group than that in the control group, while the incidence of neonatal asphyxia was significantly lower. Conclusions This study suggested that the long distance electronic FHR monitoring by telephone was a reliable, sensitive and applicable method of self monitoring for pregnant woman at home, use of this system could decrease the incidence of fetal distress, brain damage and perinatal mortality, thus improves the quality of perinatal care.
Keywords:Heart rate  fetal  Fetal  monitoring  Fetal distress  Telephone