首页 | 本学科首页   官方微博 | 高级检索  
检索        


A robotic system for delivering novel real-time,movement dependent perturbations
Institution:1. Department of Mechanical Engineering, FEI University, Sao Bernardo do Campo, SP, Brazil;2. Physical Education and Physiotherapy Faculty, Federal University of Amazonas, Amazonas, Brazil;3. Physical Therapy, Speech and Occupational Therapy Department, School of Medicine, University of Sao Paulo, Sao Paulo, SP, Brazil;1. Faculty of Kinesiology, University of Calgary, 2500 University Dr NW, Calgary, AB T2N 1N4, Canada;2. Running Injury Clinic, Calgary, Canada;3. Faculty of Nursing, University of Calgary, Calgary, Canada;1. Occupational Health and Safety Research Institute Robert-Sauvé, Montreal, Quebec, Canada;2. Sensory Motor Performance Program, Rehabilitation Institute of Chicago, Chicago, IL, USA;4. Biomedical Engineering Department, McGill University, Montreal, Canada;5. School of Physiotherapy and Occupational Therapy, McGill University, Montreal, Canada;6. Centre for Interdisciplinary Research in Rehabilitation of Greater Montreal (CRIR), Montreal Rehabilitation Institute, Montreal, Canada
Abstract:Perturbations are often used to study movement control and balance, especially in the context of falling. Most often, discrete perturbations defined prior to the experiment are used to mimic external disturbances to balance. However, the largest proportion of falls is due to self-generated errors in weight shifting. Inspired by self-generated weight shifting errors, we created a novel, continuous mediolateral perturbation proportional to subjects' mediolateral center of mass movement with minimal delays. This perturbation was delivered by a robotic platform controlled by a real time Matlab Simulink model using kinematic data from a marker positioned at subjects' L5 as input. Fifteen healthy young adults stood as still as possible atop the robotic platform with their eyes closed. We evaluated the performance of the perturbation in terms of accuracy and delay relative to the input signal by using cross-correlations. The perturbations were accurate (r = −0.984), with delays of 154 ms. Such systematic perturbation significantly affected mediolateral sway, increasing its range (from 5.56 ± 3.72 to 9.58  ± 4.83 mm, p = 0.01), SD (from 1.08 ± 0.74 to 1.72 ± 0.74 mm, p  = 0.02), and mean power frequency (from 0.08 ± 0.05 to 0.25 ± 0.17 Hz, p < 0.01). These perturbation characteristics enable inducing systematic, movement-dependent perturbations and open the door for future studies investigating self-generated movement errors.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号