首页 | 本学科首页   官方微博 | 高级检索  
检索        


The Feasibility of Translaminar Screws in the Subaxial Cervical Spine: Computed Tomography and Cadaveric Validation
Authors:Woojin Cho  Jason T Le  Adam L Shimer  Brian C Werner  John A Glaser  Francis H Shen
Institution:Department of Orthopaedic Surgery, Albert Einstein College of Medicine/Montefiore Medical Center, New York, NY, USA.;*Department of Orthopaedic Surgery, Banner Estrella Medical Center, Phoenix, AZ, USA.;Department of Orthopaedic Surgery, University of Virginia School of Medicine, Charlottesville, VA, USA.;Department of Orthopaedic Surgery, Medical University of South Carolina, Charleston, SC, USA.
Abstract:BackgroundThe use of translaminar screws may serve as a viable salvage method for complicated cases. To our understanding, the study of the feasibility of translaminar screw insertion in the actual entire subaxial cervical spine has not been carried out yet. The purpose of this study was to report the feasibility of translaminar screw insertion in the entire subaxial cervical spine.MethodsEighteen cadaveric spines were harvested from C3 to C7 and 1-mm computed tomography (CT) scans and three-dimensional reconstructions were created to exclude any bony anomaly. Thirty anatomically intact segments were collected (C3, 2; C4, 3; C5, 3; C6, 8; and C7, 14), and randomly arranged. Twenty-one segments were physically separated at each vertebral level (group S), while 9 segments were not separated from the vertebral column and left in situ (group N–S). CT measurement of lamina thickness was done for both group S and group N–S, and manual measurement of various length and angle was done for group S only. Using the trajectory proposed by the previous studies, translaminar screws were placed at each level. Screw diameter was the same or 0.5 mm larger than the proposed diameter based on CT measurement. Post-insertion CT was performed. Cortical breakage was checked either visually or by CT.ResultsWhen 1° and 2° screws of the same size were used, medial cortex breakage was found 13% and 33% of the time, respectively. C7 was relatively safer than the other levels. With larger-sized screws, medial cortex breakage was found in 47% and 46% of 1° and 2° screws, respectively. There were no facet injuries due to the screws in group N–S.ConclusionsTranslaminar screw insertion in the subaxial cervical spine is feasible only when the lamina is thick enough to avoid any breakage that could lead to further complications. The authors do not recommend inserting translaminar screws in the subaxial cervical spine except in some salvage cases in the presence of a thick lamina.
Keywords:Subaxial cervical spine  Translaminar screws  Feasibility  Cadaver  Validation
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号