首页 | 本学科首页   官方微博 | 高级检索  
     

一种新型的可检测不同人工晶状体植入术后功能视力的模型眼
引用本文:徐仁凤,黄振平,王华春,赵德高,丁亮,薛春燕,吴勇. 一种新型的可检测不同人工晶状体植入术后功能视力的模型眼[J]. 国际眼科杂志, 2006, 6(6): 1233-1236
作者姓名:徐仁凤  黄振平  王华春  赵德高  丁亮  薛春燕  吴勇
作者单位:210002,中国江苏省南京市,南京军区南京总医院眼科;210002,中国江苏省南京市,南京大学数学系;210013,中国江苏省南京市,中国电子科技集团第14研究所
摘    要:目的:通过这种新型的模型眼比较各种人工晶状体(以Tecnis为代表的非球面晶状体、以Array为代表的多焦晶状体及以EPOCH为代表的传统单焦球面晶状体)植入术后的功能视力。方法:我们这种新型的模型眼是根据理论模型眼的光学特性设计而来的。该模型眼是由一个焦距为35mm的球面设计的摄影镜头、一个置于房水的人工晶状体、一个电荷耦合照相机(CCDcamera)构成,图像分析采用目前国际上标准的商业化遥感处理软件系统。结果:模型眼和人眼具有相似的调制传递函数(modula-tiontransferfrequency,MTF)。模型眼所成的像和植入人工晶状体的眼睛所成的像相似,光阑的孔径和人工晶状体的屈光度可以改变,也可将镜片置于摄影镜头之前。结论:该模型眼能够即时的给出人工晶状体植入术后所成的像,让我们可以直接观察到模型眼构成的图像而不是数据,并能显示出各种人工晶状体的差异。

关 键 词:模型眼  人工晶状体  调制传递函数  对比敏感度
收稿时间:2006-10-17
修稿时间:2006-12-10

Eye model for inspecting the functional vision of IOLs
Ren-Feng Xu,Zhen-Ping Huang,Hua-Chun Wang,De-Gao Zhao,Liang Ding,Chun-Yan Xue,Yong Wu. Eye model for inspecting the functional vision of IOLs[J]. International Eye Science, 2006, 6(6): 1233-1236
Authors:Ren-Feng Xu  Zhen-Ping Huang  Hua-Chun Wang  De-Gao Zhao  Liang Ding  Chun-Yan Xue  Yong Wu
Affiliation:1.Department of Ophthalmology, Nanjing General Hospital of Nanjing Military Command, Chinese PLA, Naijing 210002, Jiangsu Province, China;2.Department or Mathematics, Nanjing University,Nanjing 210002, Jiangsu Province, China;3.China Electronics Technology Group Corporation, the 14^th Research Institute, Nanjing210013, Jiangsu Province, China
Abstract:AIM: To inspect and compare the functional vision of an aspheric intraocular lens (Tecnis) with those of conventional monofocal silicone and acrylic intraocular lens and multifocal intraocular lens (Array). METHODS: The IOLs were tested in the eye model, which was designed to be optically equivalent to the theoretical eye model. The eye model is a combination of a spherical photographic lens with 35mm focal length ( IOL put in a water cell) and a charge coupled device (CCD) camera. The images constructed by the lenses are observed on a monitor of personal computer and the contrasts of the images are analyzed by using commercial image processing software. RESULTS: The modulation transfer function of the eye model equals the scale produced by the theoretical eye model. The images constructed by changing the diameter of aperture stop and IOL. CONCLUSION: The proposed eye model is useful for testing functional vision and for inspecting differences of intraocular lens.
Keywords:eye model  intraocular lens  modulation transfer function  contrast sensitivity
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏