重复离心对监测碳酸锂药物浓度可靠性研究
引用本文:沈琪琳,沈珩,吕惠娟,王志勤,吕壮伟,周位强. 重复离心对监测碳酸锂药物浓度可靠性研究[J]. 现代预防医学, 2012, 39(18): 4783-4784
作者姓名:沈琪琳  沈珩  吕惠娟  王志勤  吕壮伟  周位强
作者单位:1. 新乡医学院第二附属医院,河南新乡,453002
2. 新乡医学院医学检验系11级专生本检验2班
3. 新乡卫生学校
基金项目:河南省科技攻关资助项目(0124170744)
摘    要:目的 针对锂(Li+)盐的治疗剂量(0.4~1.5mmol/L)与中毒剂量(1.6mmol/L)十分接近但又难以避免的状况,探讨样本反复离心后Li+浓度监测的可靠性.方法 选择临床服用碳酸锂治疗达稳态的住院患者,采集血清及肝素钠抗凝血标本,采用离子选择电极直接法分别测定Li+、钾(K+)、钠(Na+)、氯(Cl-)离子浓度,比较对照组和研究组的差异.结果 血清重复离心后K+浓度有升高趋势,但差异无统计学意义(P>0.05),血浆组K+浓度重复离心后显著升高(P<0.01),同时血清K+浓度显著高于血浆(P<0.001);重复离心对血清Na+、Cl-浓度无影响(P>0.05);虽然血浆Na+、Cl-浓度高于血清(P< 0.001),并随离心次数增加显著下降(P< 0.001),但无临床实用价值.结论 临床上基于某些无法抗拒的原因所导致的反复离心样本对Li+浓度监测无影响,可以认为是安全和有效的,但为了提高对临床的应答速度而使用肝素抗凝血测定Li+、K+、Na+浓度,应建立新的参考范围.

关 键 词:        药物浓度  离子选择电极

Study on the reliability of monitoring for concentration of lithium carbonate by repeat centrifugation
SHEN Qi-lin , SHEN Heng , LV Hui-juan , WANG Zhi-qin , LV Zhuang-wei , ZHOU Wei-qiang. Study on the reliability of monitoring for concentration of lithium carbonate by repeat centrifugation[J]. Modern Preventive Medicine, 2012, 39(18): 4783-4784
Authors:SHEN Qi-lin    SHEN Heng    LV Hui-juan    WANG Zhi-qin    LV Zhuang-wei    ZHOU Wei-qiang
Affiliation:. The Second Affiliated Hospital of Xinxiang Medical College,Xinxiang,Henan 453002,China
Abstract:OBJECTIVE To explore the reliability of monitoring for concentration of lithium carbonate by repeat centrifugation,because the therapeutic dose of Lithium(0.4-1.5mmol/L)is close to its toxic dose(1.6mmol/L).METHODS The concentrations of Li+,K+,Na+ and Cl-in serum samples,collected from taking lithium in treatment of the hospitalized patients,were determined by the use of ion selective electrode.RESULTS There was an increasing trend about the concentration of serum K+,but there was no significant difference(P﹥0.05)between the two groups.Meanwhile,the concentration of K+ in plasma group wAS significantly increased after repeated centrifugation(P﹤0.01),and the concentration of serum K+ was significantly higher than plasma K+(P﹤0.001);There was no effect on the concentration of serum Na+ after repeating centrifugation(P﹥0.05);Although the concentration of plasma Na+,Cl-was significantly higher than that in serum(P﹤0.001),which was decreased significantly after repeat centrifugation(P﹤0.001),but there was no clinical value.CONCLUSION It can be considered safe and effective to detect the concentration of Li+ because of some irresistible reasons caused by repeated centrifugation,however,it should be established a new reference range if using heparin to determine the concentration of Li+,K+,Na+ in order to meet the requirements of clinical.