首页 | 本学科首页   官方微博 | 高级检索  
     


A Randomized,Controlled Trial to Investigate the Effect of Ciclesonide and Beclomethasone Dipropionate on Eye Lens Opacity
Authors:Leo T. Chylack Jr.  Gary N. Gross  Andrew Pedinoff  The Ciclesonide Lenticular Safety Study Group
Affiliation:1. Department of Ophthalmology, Harvard Medical School, Boston, Massachusetts;2. Brigham and Women's Hospital, Center for Ophthalmic Research, Boston, Massachusetts;3. Pharmaceutical Research &4. Consulting, Dallas, Texas;5. Princeton Center for Clinical Research, Princeton, New Jersey
Abstract:Background. Inhaled corticosteroids (ICS) are recommended first-line therapy for the treatment of persistent asthma. However, reports from observational studies have suggested that the use of ICS may be associated with systemic adverse events, such as glaucoma and cataract (opacity of the lens) formation. Objective. To compare two ICS over 1 year regarding the formation/progression of lenticular opacities in patients with asthma. Methods. Adults (≥ 18 years of age) with moderate-to-severe asthma were randomized to ciclesonide 640 μ g/day (n = 785) or beclomethasone dipropionate 640 μ g/day (n = 783) in a multinational, double-blind, active-controlled, parallel-group study. The primary endpoint was the occurrence of a positive Class I grading shift (increase [worsening] in Lens Opacities Classification System [LOCS] III score of ≥ 0.5 for nuclear opalescence, ≥ 0.8 for cortical opacification, or ≥ 0.5 for posterior subcapsular opacification, or cataract surgery) in either eye at any visit over the 12-month, double-blind treatment period. Results. Mean changes (± standard error) in nuclear opalescence and cortical and posterior subcapsular opacification were small and similar between groups (ciclesonide 640 μ g/day: 0.10 ± 0.02, 0.07 ± 0.02 and 0.04 ± 0.01, respectively; beclomethasone dipropionate 640 μ g/day: 0.11 ± 0.02, 0.09 ± 0.02 and 0.03 ± 0.01, respectively). Class I shifts were observed in 34.3% versus 36.8% of ciclesonide-treated and beclomethasone dipropionate-treated patients, respectively. Ciclesonide 640 μ g/day was non-inferior to beclomethasone dipropionate 640 μ g/day regarding Class I shifts (risk ratio of ciclesonide to beclomethasone dipropionate, 0.940 [95% confidence interval, 0.820–1.077]); the 95% confidence interval upper bound was lower than the pre-specified non-inferiority bound of 1.333 (p < 0.0001), thereby excluding the possibility of higher risk ratio values. Conclusions. Mean changes in LOCS III scores were very small in both groups. Treatment with ciclesonide 640 μ g/day or beclomethasone dipropionate 640 μ g/day for 1 year has a minimal impact on lenticular opacities development and/or progression.
Keywords:ciclesonide  beclomethasone dipropionate  lenticular opacities  asthma  cataract
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号