同位素稀释液相色谱串联质谱法测定血清肌酐
引用本文:张天娇,赵海舰,张传宝,张江涛,胡翠华,闫颖,王冬环,汪静,谢洁红,马嵘,申子瑜,陈文祥.同位素稀释液相色谱串联质谱法测定血清肌酐[J].中华检验医学杂志,2009,32(5).
作者姓名:张天娇  赵海舰  张传宝  张江涛  胡翠华  闫颖  王冬环  汪静  谢洁红  马嵘  申子瑜  陈文祥
作者单位:卫生部临床检验中心,卫生部北京医院,100730
基金项目:国家科技支撑计划,国家高技术研究发展计划(863计划) 
摘    要:目的 建立一种使用同位素稀释液相色谱串联质谱法(ID-LC/MS/MS)测定血清肌酐的候选参考方法.方法 以2H3]肌酐为内标,用无水乙醇沉淀血清中的蛋白质,用氯仿纯化上清液,用液相色谱串联质谱分离测定,以包括法定量.结果 血清肌酐测定的批内、批间和总变异系数的平均值分别为0.57%(范围0.52%~0.61%)、0.43%(范围0.11%~0.59%)和0.73%(范围0.62%~0.83%).加样回收试验的回收率范围为99.09%~101.13%.分析两种参考物质SRM909b和SRM 967b,测定结果与认定值的偏差小于0.4%.结论 建立了ID-LC/MS/MS法测定血清肌酐的方法,方法准确、精密、简便,可望作为血清肌酐测定的参考方法.

关 键 词:肌酸酐  同位素标记  色谱法  液相  串联质谱法

Determination of serum creatinine by isotope dilution liquid chromatography tandem mass spectrometry: a candidate reference method
ZHANG Tian-jiao,ZHAO Hai-jian,ZHANG Chuan-bao,ZHANG Jiang-tao,HU Cui-hua,YAN Ying,WANG Dong-huan,WANG Jing,XIE Jie-hong,MA Rong,SHEN Ziyu,CHEN Wen-xiang.Determination of serum creatinine by isotope dilution liquid chromatography tandem mass spectrometry: a candidate reference method[J].Chinese Journal of Laboratory Medicine,2009,32(5).
Authors:ZHANG Tian-jiao  ZHAO Hai-jian  ZHANG Chuan-bao  ZHANG Jiang-tao  HU Cui-hua  YAN Ying  WANG Dong-huan  WANG Jing  XIE Jie-hong  MA Rong  SHEN Ziyu  CHEN Wen-xiang
Abstract:Objective To develop a candidate reference method for the measurement of creatinine in human serum based on isotope dilution liquid chromatography tandem mass spectrometry (ID-LC/MS/MS). Methods An isotopically labeled internal standard <'2>H<,3>] creatinine was added to the serum sample and equilibrated with the endogenous creatinine. The samples were treated with anhydrous ethanol to remove proteins by precipitation. After being washed with chloroform for further clean-up, the samples were analyzed by LC/MS/MS. Serum creatinine was quantified by a bracketing calibration. Results The within-run, between-run and total coefficients of variation ranged from 0.52% to 0.61%, 0.11% to 0.59% and 0.61% to 0.83%, and the averages were 0.57%, 0.43% and 0.73%, respectively. The analytical recoveries ranged from 99.09% to 101.13% with an average of 100.3%.The results of analyzing the certified reference material SRM 909b (Level Ⅰ and Ⅱ) and SRM 967b showed biases of less than 0.4%. Conclusions An ID-LC/MS/MS method for measuring serum creatinine has been developed. The method is highly precise and accurate and may be used as a candidate reference method for serum creatinine measurements.
Keywords:Creatinine  Isotope labeling  Chromatography  liquid  Tandem mass spectrometry