Diagnostic imaging for suspected pulmonary embolism during pregnancy and postpartum: A comparative radiation dose study
Authors:Jodie Tester  Megan Rees  Diane Pascoe  Victoria Earl  Paul Einsiedel  Wen Kwang Lim  Louis Irving  Gary Hammerschlag
Affiliation:1. Faculty of Medicine, Dentistry and Health Sciences, University of Melbourne, Melbourne, Victoria, Australia;2. Faculty of Medicine, Dentistry and Health Sciences, University of Melbourne, Melbourne, Victoria, Australia

Department of Respiratory Medicine and Sleep Disorders, Royal Melbourne Hospital, Melbourne, Victoria, Australia;3. Department of Radiology, Royal Melbourne Hospital, Melbourne, Victoria, Australia;4. Faculty of Medicine, Dentistry and Health Sciences, University of Melbourne, Melbourne, Victoria, Australia

Department of Medicine, Royal Melbourne Hospital, Melbourne, Victoria, Australia;5. Department of Respiratory Medicine and Sleep Disorders, Royal Melbourne Hospital, Melbourne, Victoria, Australia

Abstract:

Introduction

To compare the radiation dose exposure and diagnostic efficiency of computed tomographic pulmonary angiography (CTPA) and ventilation/perfusion imaging (V/Q) for clinically suspected pulmonary embolism (PE) in pregnant and postpartum women in a tertiary hospital setting.

Methods

A retrospective cohort study of 473 pregnant and postpartum women referred for CTPA or V/Q for clinically suspected PE between January 2013 and December 2018 at a tertiary hospital. Maternal effective radiation dose, breast-absorbed radiation dose and fetal-absorbed dose estimates were calculated. Diagnostic yield was evaluated from radiological findings.

Results

Computed tomographic pulmonary angiography (CTPA) was more commonly used for the imaging of suspected PE in pregnant and postpartum populations (51.9% vs. 48.1% and 77.1% vs. 22.9%, respectively). CTPA was associated with higher maternal effective and breast-absorbed doses (maternal effective CTPA 4.7 (±2.9) mSv (millisievert), V/Q 1.7(±0.8) mSv (mean difference 2.93 mSv P < 0.001), and breast-absorbed CTPA 8.0 (±5.2) mGy (milligray), V/Q 0.3 (±0.1) (mean difference 7.67 mGy P < 0.001), respectively). Fetal radiation dose exposure was low. The incidence of positive PE was 5.5%. Indeterminate rates of CTPA and V/Q were 3.0% and 5.5% (P = 0.176), respectively.

Conclusions

Compared to V/Q, CTPA is associated with higher maternal and breast radiation dose; however, modern CT scanners achieve lower radiation doses than historically described. Fetal radiation dose was comparably low. The diagnostic yield of the imaging modalities in pregnant and postpartum women is similar. Revision of guidelines should occur with the advances in CT technology.
Keywords:diagnostic imaging  postpartum  pregnancy  pulmonary embolism  radiation dose