Abstract: | ABSTRACT: BACKGROUND: The main objective of this study will be to determine the effects of a new advanced sternum external fixation (Stern-E-Fix) corset on prevention of sternal instability and mediastinitis in high-risk patients. METHODS: This prospective, randomized study (January 2009 -- June 2011) comprised 750 male patients undergoing standard median sternotomy for cardiac procedures (78% CABG). Patients were divided in two randomized groups (A, n = 380: received a Stern-E-Fix corset postoperatively for 6 weeks and B, n = 370: control group received a standard elastic thorax bandage). In both groups, risk factors for sternal dehiscence and preoperative preparations were similar. RESULTS: Wound infections occurred in n = 13 (3.42%) pts. in group A vs. n = 35 (9.46%) in group B. In group A, only 1 patient presented with sternal dehiscence vs. 22 pts. in group B. In all 22 patients, sternal rewiring followed by antibiotic therapy was needed. Mediastinitis related mortality was none in A versus two in B. Treatment failure in group B was more than five times higher than in A (p = 0.01); the mean length of stay in hospital was 12.53 +/- 7.4 days (A) versus 17.9 +/- 15.1 days (B)(p = 0.02). Re-operation for sternal infection was 4 times higher in group B. Mean ventilation time was relatively longer in B (2.5 vs. 1.28 days) (p = 0.01). The mean follow-up period was 8 weeks (range 6 -- 12 weeks). CONCLUSIONS: We demonstrated that using an external supportive sternal corset (Stern-E-Fix) yields a significantly better and effective prevention against development of sternal dehiscence and secondary sternal infection in high-risk poststernotomy patients. |