Bone alterations at implant‐supported FDPs in relation to inter‐unit distances: a 5‐year radiographic study
Authors:Moontaek Chang  Jan L Wennström
Institution:1. Department of Periodontology, Institute of Odontology, The Sahlgrenska Academy at University of Gothenburg, G?teborg, Sweden;2. Department of Periodontology, School of Dentistry, Chonbuk National University, Chonju, Korea.
Abstract:Objectives: The aim of this 5‐year study was to longitudinally evaluate bone alterations around implants with a conical implant–abutment interface in relation to implant–tooth and inter–implant distances. Material and methods: The patient sample comprised 43 partially dentate patients with a total of 48 implant‐supported fixed dental prostheses (FDPs) supported by 130 Astra Tech® implants. Following FDP placement (baseline), the patients were enrolled in an individually designed supportive care program. Radiographic examinations were performed at the time of FDP installation, 1 and 5 years of follow‐up. Variables regarding implant position and proximal bone topography at tooth/implant units (n=36) and implant/implant units (n=67) were assessed with the use of a software program after scanning of the radiographs. Results: At tooth/implant units, the mean 5‐year marginal bone loss at the tooth, the implant and the mid‐proximal bone crest was 0.1, 0.4 and 0.2 mm, respectively. The mean longitudinal bone loss at the implant/implant units was 0.5 mm at the implants and 0.3 mm mid‐proximally. Multilevel regression analysis revealed that at implant/implant units, the change in the bone‐to‐implant contact level was a significant predictor with regard to the 5‐year mid‐proximal bone‐level change, whereas the horizontal inter‐unit distance showed a borderline significance (P=0.052). At tooth/implant units, no statistically significant associations were identified. Conclusions: The results of this 5‐year study revealed differences between inter‐implant and tooth–implant proximal areas with regard to bone crest alterations and associated factors. To cite this article:
Chang M, Wennström JL. Bone alterations at implant‐supported FDPs in relation to inter‐unit distances: a 5‐year radiographic study.
Clin. Oral Impl. Res. 21 , 2010; 735–740.
doi: 10.1111/j.1600‐0501.2009.01893.x
Keywords:dental implants  esthetics  implant–  tooth distance  inter‐implant distance  peri‐implant bone alterations
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号