首页 | 本学科首页   官方微博 | 高级检索  
检索        


Effect of age on anterior chamber angle configuration in Asians determined by anterior segment optical coherence tomography; clinic‐based study
Authors:Mi Hyun Cheon  Kyung Rim Sung  Eun Hee Choi  Sung Yong Kang  Jung Woo Cho  Suhwan Lee  Jae Yong Kim  Hung Won Tchah  Michael S Kook
Institution:1. Department of Ophthalmology, College of Medicine, University of Ulsan, Asan Medical Center, Seoul, Korea;2. Department of Biostatistics, Yonsei University College of Medicine, Seoul, Korea
Abstract:Acta Ophthalmol. 2010: 88: e205–e210

Abstract.

Purpose: To evaluate the distribution of anterior chamber angle (ACA) parameters and to assess association of these parameters with age in Asian subjects. Methods: Four hundred and thirty‐nine consecutive Korean subjects aged from 30 to 89 were enrolled from a university clinic. All participants were scanned using anterior segment optical coherence tomography (AS‐OCT, Visante, version 2.0). We measured ACA parameters such as anterior chamber depth (ACD), angle opening distance at 500 and 750 μm (AOD500,750), angle recess area at 500 and 750 μm (ARA500,750), trabecular iris space area at 500 and 750 μm (TISA500,750), and determined age‐related changes in these parameters with use of a linear mixed effect model that adjusted for gender, axial length, intraocular pressure, and keratometry data. Slopes of ACA parameters as a function of age were determined. For various AS‐OCT parameters, the normalized slope was calculated by dividing the slope by the mean value. Results: All analysed ACA parameters decreased with age in both nasal and temporal quadrants. Axial length and keratometry data were significant covariates for ACA changes. The slopes of ACD were ?0.02396 mm/year, AOD500, ARA500, and TISA500 measured at the temporal angle were ?0.00634 mm/year, ?0.0019 mm2/year, and ?0.00177 mm2/year, respectively. There was no age‐dependent difference in central corneal thickness (p value; 0.4597) Based on the normalized slopes, the AOD showed the steepest slope at both temporal and nasal sectors. Conclusion: All ACA parameters assessed by AS‐OCT, which accounted for other ocular biometric parameters, showed significant negative slopes with increasing age. These results should be considered when assessing changes in the anterior chamber over time.
Keywords:age  angle closure  anterior chamber angle  anterior segment optical coherence tomography
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号