首页 | 本学科首页   官方微博 | 高级检索  
     

气相色谱/质谱联用测定室内灰尘中邻苯二甲酸酯
引用本文:陆晓梅,张 绮,张晓玲,董海峰,张正东,王炳玲. 气相色谱/质谱联用测定室内灰尘中邻苯二甲酸酯[J]. 南京医科大学学报(自然科学版), 2012, 0(7): 1038-1042
作者姓名:陆晓梅  张 绮  张晓玲  董海峰  张正东  王炳玲
作者单位:南京医科大学公共卫生学院卫生检验学系,江苏 南京 210029;南京医科大学公共卫生学院职业医学与环境卫生学系,江苏 南京 210029;南京医科大学公共卫生学院卫生检验学系,江苏 南京 210029;南京医科大学公共卫生学院康达学院,江苏 南京 210029;南京医科大学公共卫生学院职业医学与环境卫生学系,江苏 南京 210029;南京医科大学公共卫生学院职业医学与环境卫生学系,江苏 南京 210029
基金项目:国家自然科学基金面上项目(81072268);江苏省自然科学基金面上项目(BK2010535);江苏省博士后基金(1001017C);江苏高校优势学科建设工程资助项目
摘    要:目的:建立气相色谱/质谱联用测定室尘中7种常见邻苯二甲酸酯(phthalate esters,PEs)的分析方法?方法:用吸尘器采集室尘,用正己烷超声提取室尘中的PEs,浓缩后用正己烷定容至0.2 ml,气相色谱/质谱仪分析测定?结果:7种PEs 22 min内彼此完全分离,在5~2 000 ng/ml范围内线性关系良好,相关系数r均 > 0.998,相对标准偏差为5.66%~18.03%,加标回收率为87.73%~110.63%?结论:该方法测定室尘中PEs经济?快速?简便?灵敏,重现性好,符合大样本量室尘样品中PEs的测定要求?

关 键 词:气相色谱/质谱   室内灰尘   邻苯二甲酸酯
收稿时间:2012-03-12

Determination of phthalate esters in house dust by gas chromatography/mass spectrometry
LU Xiao-mei,ZHANG Qi,ZHANG Xiao-ling,DONG Hai-feng,ZHANG Zheng-dong and WANG Bing-ling. Determination of phthalate esters in house dust by gas chromatography/mass spectrometry[J]. Acta Universitatis Medicinalis Nanjing, 2012, 0(7): 1038-1042
Authors:LU Xiao-mei  ZHANG Qi  ZHANG Xiao-ling  DONG Hai-feng  ZHANG Zheng-dong  WANG Bing-ling
Affiliation:Department of Hygienic Analysis and Detection,School of Public Health,NJMU,Nanjing 210029,China;Department of Occupational Medicine and Environmental Health,School of Public Health,NJMU,Nanjing 210029,China;Department of Hygienic Analysis and Detection,School of Public Health,NJMU,Nanjing 210029,China;Kangda College,NJMU,Nanjing 210029,China;Department of Occupational Medicine and Environmental Health,School of Public Health,NJMU,Nanjing 210029,China;Department of Occupational Medicine and Environmental Health,School of Public Health,NJMU,Nanjing 210029,China
Abstract:Objective:To establish a simple method for determination of 7 phthalate esters (PEs) by gas chromatography/mass spectrometry (GC/MS). Methods:Vacuum cleaner was used for gathering the house dust,and n-hexane was added and extraction was performed in an ultrasonic bath. The supernatant was concentrated and then added with n-hexane to 0.2 ml. PEs were determined by GC/MS. Results:Seven PEs had highly efficient separation within 22 minutes and showed good linearity within 5~2 000 ng/ml range with correlation coefficients all beyond 0.998. The relative standard deviations were 5.66%~18.03%,and the recoveries were 87.73%~110.63%. Conclusion:This method was a economic,fast,simple,sensitive and reproducible enough for settled-dust PEs measurements in house dust with large sample size.
Keywords:gas chromatography/mass spectrometry  house dust  phthalate esters