Immunoaffinity columns and determination of ochratoxin A in cereals by HPLC. Part II. Evaluation of extraction using acetonitrile/water |
| |
Authors: | Czerwiecki Ludwik Czyzyk Kamila Wilczyńska Grazyna Kwiecień Agnieszka |
| |
Institution: | Zak?ad Analizy Zywno?ci, Instytut Biotechnologii Przemys?u Rolno-Spozywczego, 02-532 Warszawa, ul. Rakowiecka 36. czerwiecki@ibprs.pl |
| |
Abstract: | Ochratoxin A from wheat and rye grain was extracted with acetonitrile:water (60:40). After clean-up of extracts using immunoaffinity columns (IAC), ochratoxin was determined by high-performance liquid chromatography using C18 column and fluorometric detection at 330 nm excitation and 460 nm emission. The mean recovery of ochratoxin A at fortification levels 0.1-100 microg/kg, was 74-89%. The limits of detection (LOD) and quantification (LOQ) were 0.015 and 0.025 microg/kg, respectively. The positive results were confirmed by reaction with BF3 complex in methanol. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|