首页 | 本学科首页   官方微博 | 高级检索  
     

艾康恶性疟/间日疟免疫层析检测试剂盒效果评价
引用本文:孙晓东,邓艳,张再兴,冯舜,罗存富,苏红梅,陈忠明,汪红蕾,刘慧,汪丽波,徐万红. 艾康恶性疟/间日疟免疫层析检测试剂盒效果评价[J]. 中国热带医学, 2007, 7(1): 28-29
作者姓名:孙晓东  邓艳  张再兴  冯舜  罗存富  苏红梅  陈忠明  汪红蕾  刘慧  汪丽波  徐万红
作者单位:1. 云南省寄生虫病防治所,云南,思茅,665000
2. 思茅市医院感染科,云南,思茅,665000
3. 思茅市翠云区疾病预防控制中心,云南,思茅,665000
4. 思茅市疾病预防控制检验科,云南,思茅,665000
5. 艾康生物技术(杭州)有限公司,浙江,杭州,310023
基金项目:艾康生物技术(杭州)有限公司资助项目
摘    要:目的 评价艾康恶性疟/间日疟(P.f/P.v)胶体金免疫层析检测试剂盒诊断疟疾效果。方法 以镜检法为金标准。采用盲法实验室测试疟痰阳性和阴性血样。结果 共测试331例血样,其中疟痰血样121倒。对疟疾的灵敏性和特异性分别为92.56%和98.57%,与镜检符合率为96.38%;其中恶性疟的灵敏性和特异性分别为1130.00%和98.57%,重复性为100.00%;对间日疟的灵敏性和特异性分别为86.96%和100.00%,恶性疟和间日疟之间无交叉反应。结论 艾康P.f./P.v肢体金免疫层析检测试剂盒诊断疟痰具有快速、简便、准确、直观以及不需要特殊仪器优点,能同时诊断单纯恶性疟和单纯间日疟,但不能鉴别诊断混合感染。

关 键 词:艾康(P.f/P.v)免疫层析检测试剂盒  诊断  疟疾  恶性疟  间日疟
文章编号:1009-9727(2007)1-28-02
收稿时间:2006-03-10
修稿时间:2006-03-10

Evaluation of results of ACON Malaria p. F./p. V. Gold Immunochromotographic Kit in diagnosis of Plasmodium falciparum and Plasmodium vivax
SUN Xiao - dong, DENG Yan, ZHANG Zai - xing,et al.. Evaluation of results of ACON Malaria p. F./p. V. Gold Immunochromotographic Kit in diagnosis of Plasmodium falciparum and Plasmodium vivax[J]. China Tropical Medicine, 2007, 7(1): 28-29
Authors:SUN Xiao - dong   DENG Yan   ZHANG Zai - xing  et al.
Affiliation:SUN Xiao - dong, DENG Yan, ZHANG Zai - xing, et al.
Abstract:Objective To evaluate the efficacy of ACON Malaria P.f/P.v Gold Immunochromatographic Kit(ACON Kit)in de- tecting P.Falciparum and P.Vivax.Methods The microscopy examination was regarded as gold standard and negative and positive blood samples were detected in laboratory using ACON Kit by the blind method.Results A total of 331 blood samples were detected and 121 were positive for malaria,the sensitivity and specificity of ACON Kit were 92.56% and 98.57 ,respectively. The coincidence rate of ACON Kit with microscopy was 96.38 %.The sensitivity and specificity of ACON Kit in detection of P. falciparum were 100% and 98.57%,respectively with reproducible rate of 100%.The sensitivity and specificity of ACON Kit in detection of P.vivax were 86.96% and 100%,respectively.There no cross reaction between P.falciparum and P.vivax was no- ticed.Conclusion ACON Kit could rapidly,easily,exactly,intuitively detect single P.falciparum and P.vivax simultaneously. But ACON Kit could not entirely replace microscopy examination as it can not detect mixed infections.
Keywords:ACON Malaria P. UP. v Gold Immunochromatographie Kit   DiagnoSis   Malaria   Plasmodium falciparum   Plasmodium vivax
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号