多通道人工耳蜗使用者电刺激速率辨别与声调识别的关系
引用本文:魏朝刚,曾凡钢.多通道人工耳蜗使用者电刺激速率辨别与声调识别的关系[J].中华耳鼻咽喉科杂志,1999,34(2):84-88.
作者姓名:魏朝刚  曾凡钢
摘    要:用心理特理学的方法探讨多通道人工耳蜗使用者单个电极速率辨别与声调及言语识别的关系,为国人使用多通道人工耳蜗效果的评估及治语音编码方案的设计提供依据。方法4例语后聋成人人工耳蜗使用者参与测试。

关 键 词:语音学  音调辨别  电刺激  人工耳蜗

Rate discrimination and tone recognition in mandarin-speaking cochlear-implant listeners]
C Wei,K Cao,Z Wang.Rate discrimination and tone recognition in mandarin-speaking cochlear-implant listeners][J].Chinese Journal of Otorhinolaryngology,1999,34(2):84-88.
Authors:C Wei  K Cao  Z Wang
Institution:Department of Otorhinoloaryngology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing 100730.
Abstract:OBJECTIVE: To explore the relationship between the rate discrimination and the tone recognition with psychophysical method, and provide a basis for evaluating the results from mandarin-speaking cochlear implantees who used multi-channel cochlear implant and designing new speech coding strategies of the speech processor. METHODS: Four postlingually-deafened adults with cochlear implant participated in this study. We used the method of constant stimuli to measure the rate discrimination as a function of the standard rate at 50, 100, 200, 400 Hz on electrode pairs (E1, E3), (E7, E9), (E14, E16), and (E20, E22), respectively. We also measured tone recognition in 25 consonant-vowel syllables, each of which has four tonal variations, resulting in a total of 100 words. These words were recorded by a male talker and were presented five times each to the implant users via their speech processors. The tone recognition results were scored in overall percent correct and analyzed by error patterns in the confusion matrix and fundamental frequency. RESULTS: The rate discrimination thresholds, defined at the 75% correct level, varied greatly among individuals and ranged from several Hz to hundreds of Hz. A three-way ANOVA indicated significant effect (P < 0.05) on rate discrimination for the standard rate, electrode position, and patient variable. The tone recognition ranged from 40% to 80% and tones 1 and 3 were more easily identified than tones 2 and 4. Preliminary analysis using linear regression revealed highly significant correlation between rate discrimination and tone recognition. CONCLUSION: These results suggest that identification of tones relies on good rate discrimination in cochlear implant listeners. Clinical rehabilitation strategies in improving rate discrimination were discussed.
Keywords:
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号