脉冲振荡法测定支气管哮喘患者呼吸阻抗
引用本文:王美琴,钮善福,李燕芹,张志凤,白春学.脉冲振荡法测定支气管哮喘患者呼吸阻抗[J].复旦学报(医学版),1999(4).
作者姓名:王美琴  钮善福  李燕芹  张志凤  白春学
作者单位:上海医科大学中山医院呼吸病研究所
摘    要:目的探讨脉冲振荡技术(IOS)法测定支气管哮喘患者呼吸阻抗的价值。方法对74例支气管哮喘患者进行呼吸阻抗的测定并与肺通气功能指标相比较。结果哮喘组共振频率(Fres)、5Hz和20Hz振荡频率时粘性阻力(R5、R20)及5Hz和20Hz振荡频率时粘性阻力差值(R5-R20)均明显高于健康组。5Hz振荡频率时电抗(X5)明显低于健康组。哮喘组Fres、R5-R20、R5和X5与用力呼气流速容量曲线参数相关,R20与用力呼气流速容量曲线参数不相关。Fres与第1秒用力呼气容积和最大呼气流速相关性最密切,相关系数分别为-0.714和-0.724。Fres、R5-R20、R5和X5诊断哮喘的敏感性分别为83.78%、67.57%、56.76%和40.54%。特异性分别为86.21%、89.66%、98.27%和94.83%。结论Fres是IOS参数中诊断哮喘的最敏感指标。IOS是诊断哮喘、判断病情轻重的一个有用工具,值得临床推广使用。

关 键 词:脉冲振荡技术  支气管哮喘  呼吸阻抗

Respiratory Impedance Measured by Impulse Oscillometry in Patients with Bronchial Asthma
Wang Meiqin,Niu Shanfu,Li Yanqin,Zhang Zhifeng,Bai Chunxue.Respiratory Impedance Measured by Impulse Oscillometry in Patients with Bronchial Asthma[J].Fudan University Journal of Medical Sciences,1999(4).
Authors:Wang Meiqin  Niu Shanfu  Li Yanqin  Zhang Zhifeng  Bai Chunxue
Abstract:Purpose To study the significance of measuring the respiratory impedance in bronchial asthma patients by impulse oscillometry method. Methods The impedance of the respiratory system was measured and compared with pulmonary ventilation function in 74 patients with bronchial asthma. Results There was a significant increase in viscidity resistance at 5 Hz and 20 Hz and the difference between them in the asthma group as compared with that of the healthy group.Reactance at 5 Hz in the bronchial asthma group was markedly lower than that in the healthy group.Resonant frequency,the difference of R 5 and R 20 ,and R 5 and X 5 correlated significantly with the selected parameters of the forced expiratory flow volume curve.No correlation was found between R 20 and forced expiratory flow volume parameters.Close correlation was found between Fres and FEV 1 and between Fres and V max , and the correlation coefficient values were -0.714 and -0.724 respectively.The sensitivity of resonant frequency,R 5-R 20 , R 5 and X 5 for the diagnosis of asthma was 83.78%,67.57%,56.76% and 40.54% respectively.The specificity of them was 86. 21%,89.66%,98.27% and 94.83% respectively. Conclusions Resonant frequency is the most sensitive index of IOS parameters for the diagnosis of bronchial asthma.IOS is a useful tool in diagnosing asthma and determining the patients'condition.It is worthful in clinical use.
Keywords:impulse oscillometry  bronchial asthma  respiratory impedance  