首页 | 本学科首页   官方微博 | 高级检索  
     


Development, implementation, and impact of acceptability criteria for serologic tests for infectious diseases
Authors:Crump John A  Corder Jennifer R  Henshaw Nancy G  Reller L Barth
Affiliation:Clinical Microbiology Laboratory, Duke University Medical Center, Duke University School of Medicine, Durham, North Carolina 27710, USA.
Abstract:Serologic testing is essential for the diagnosis of some infectious diseases and yet is fraught with potential pitfalls. All parts of the diagnostic process must be optimized to ensure that serologic tests perform adequately. Recognizing that a lack of clinical data and correctly timed, paired sera frequently led to uninterpretable serology results at our laboratory, we developed and implemented simple acceptability criteria for serologic tests. We assessed the impact of these criteria by comparing submissions and results for the year before and the year after implementation of the criteria. The number of serologic tests performed declined by 25% after implementation of the acceptability criteria, despite an increase in requests for serologic tests. Inappropriate testing of acute-phase sera alone fell from 49 to 0% (P < 0.001) for the tests monitored. Appropriate submission of paired sera rose from 9 to 19% (P = 0.006). The proportion of results classified as interpretable rose from 52 to 100% (P < 0.001). We recommend that acceptability criteria be developed and applied to samples submitted to clinical microbiology laboratories for serologic testing.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号