首页 | 本学科首页   官方微博 | 高级检索  
     


99mTc-MIBI pinhole SPECT in primary hyperparathyroidism: comparison with conventional SPECT, planar scintigraphy and ultrasonography
Authors:Thomas Carlier  Aurore Oudoux  Eric Mirallié  Alain Seret  Isabelle Daumy  Christophe Leux  Caroline Bodet-Milin  Françoise Kraeber-Bodéré  Catherine Ansquer
Affiliation:Nuclear Medicine Department, H?tel Dieu University Hospital, Nantes, France.
Abstract:Purpose A pinhole collimator is routinely used to increase the resolution of scintigraphy. This prospective study was conducted to determine the interest of 99mTc-MIBI pinhole single-photon emission computed tomography (SPECT) for the preoperative localisation of parathyroid lesions in primary hyperparathyroidism. Methods All patients underwent a neck ultrasonography (US), $$ ^{{99{text{m}}}} {text{TcO}}^{{text{ - }}}_{{text{4}}}  $$ and 99mTc-MIBI planar images and two consecutive SPECT with a parallel (C-SPECT) and a pinhole collimator (P-SPECT). P-SPECT was performed with a tilted detector equipped with a pinhole collimator and reconstructed with a dedicated OSEM algorithm. A diagnostic confidence score (CS) was assigned to each procedure considering intensity and extra-thyroidal location of suspected lesions: 0 = negative, 1 = doubtful, 2 = moderately positive, 3 = positive. The results of these preoperative localisation studies were compared with surgical, pathological and 6-month biological findings. Results Fifty-one patients cured after surgery were included. Surgery revealed 55 lesions (median weight 0.5 g, 11 in ectopy). Sensitivities of US, planar imaging, C-SPECT and P-SPECT were, respectively, 51, 76, 82 and 87%. Nine glands were only detected by tomography and five glands only by P-SPECT. $$ {^{{{text{99m}}}} {text{Tc - MIBI}}} mathord{left/  {vphantom {{^{{{text{99m}}}} {text{Tc - MIBI}}} {^{{{text{99m}}}} {text{TcO}}^{ - }_{{text{4}}} }}} right.  kern-nulldelimiterspace} {^{{{text{99m}}}} {text{TcO}}^{ - }_{{text{4}}} } $$ planar scans and P-SPECT were complementary and, when combined together, showed the highest sensitivity (93%). Compared with planar imaging and C-SPECT, P-SPECT increased CS for 42 and 53% of lesions, respectively, and contributed to markedly reduce the number of uncertain results. Conclusions A combination of planar $$ {^{{{text{99m}}}} {text{Tc - MIBI}}} mathord{left/  {vphantom {{^{{{text{99m}}}} {text{Tc - MIBI}}} {^{{{text{99m}}}} {text{TcO}}^{ - }_{{text{4}}} }}} right.  kern-nulldelimiterspace} {^{{{text{99m}}}} {text{TcO}}^{ - }_{{text{4}}} } $$ scintigraphy and P-SPECT appears to be a highly accurate preoperative imaging procedure in primary hyperparathyroidism.
Keywords:Hyperparathyroidism  Pinhole SPECT   99mTc-sestamibi  Preoperative localisation  Parathyroid scintigraphy  Parathyroid adenoma
本文献已被 PubMed SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号