The FMCA-GM assays,high throughput non-clonogenic alternatives to CFU-GM in preclinical hematotoxicity testing
Authors:Caroline Haglund  Anna Åleskog  Lena Douhan Håkansson  Martin Höglund  Stefan Jacobsson  Rolf Larsson  Elin Lindhagen
Institution:1. Department of Medical Sciences (Division of Clinical Pharmacology), Uppsala University, Uppsala, Sweden;2. Department of Medical Sciences (Division of Haematology), Uppsala University, Uppsala, Sweden;3. Department of Medical Sciences (Division of Clinical Chemistry), Uppsala University, Uppsala, Sweden;4. Department of Clinical Chemistry, Sahlgrenska University Hospital, SE-413 45 Gothenburg, Sweden
Abstract:One of the most common dose limiting adverse effects in cancer treatment is myelotoxicity. The aim of this study was to develop an in vitro method for measuring potential myelotoxic properties of a drug candidate in a high throughput setting. Human CD34+ progenitor cells from umbilical cord blood were plated in 384-well microplates with drugs in liquid culture, supplemented with specific cytokines for the granulocytopoietic-macrophage lineage. After 7 or 14 days of proliferation and differentiation the cells were analyzed using the automated non-clonogenic fluorometric microculture cytotoxicity assay (FMCA). Two types of assays setups were evaluated, the FMCA-GM7 where cells were exposed to drugs directly after thawing and cytotoxicity measured on day 7 in contrast to the FMCA-GM14 where the cells were cultured 7 days prior to plating and drug exposure, with viability analysis on day 14 of differentiation. Drug sensitivity was similar in both assays and method validation was performed using 24 drugs with known myelotoxic profile (acyclovir, bortezomib, busulfan, carboplatin, chloramphenicol, chlorpromazine, cisplatin, cytarabine, clozapine, doxorubicin, erlotinib, etoposide, 5-fluorouracil, fludarabine, gefitinib, gemcitabine, hydroxyurea, imatinib, lomustine, melphalan, sorafenib, sunitinib, taxol and 6-thioguanine). The 50% inhibitory concentrations (IC50) from the FMCA-GM7 and the FMCA-GM14 correlated highly (r = 0.83) and (r = 0.82), respectively, with IC50 from the established clonogenic assay (CFU-GM), obtained from the literature. The current data suggests that the FMCA-GM could offer a simple and robust alternative to the CFU-GM assay in preclinical hematotoxicity studies.
Keywords:Hematotoxicity  High throughput screening  FMCA  CFU-GM
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号