Intraoperative carotid artery duplex scanning in a modern series of 650 consecutive primary endarterectomy procedures
Authors:Ascher Enrico  Markevich Natalia  Kallakuri Sreedhar  Schutzer Richard W  Hingorani Anil P
Institution:Maimonides Medical Center, Brooklyn, NY 11219, USA. eascher@maimonidesmed.org
Abstract:PURPOSE: Thromboembolic complications after carotid endarterectomy are frequently associated with technical defects. We analyzed the effect of intraoperative duplex scanning in detection of significant but clinically unsuspected technical defects and residual common carotid artery (CCA) disease as a potential source of postoperative transitory ischemic attack (TIA) and stroke. METHODS: From April 2000 to April 2003, 650 consecutive primary carotid endarterectomy procedures were performed in 590 patients at a single institution by two vascular surgeons. Patients included 335 men (57%) and 255 women (43%). Indications for surgery were asymptomatic internal carotid artery (ICA) stenosis (>or=70%) in 464 patients (71%). All procedures were performed with the patient under general anesthesia, with synthetic patch angioplasty in 644 (99.1%). Major technical defects at intraoperative duplex scanning (>30% luminal internal carotid artery stenosis, free-floating clot, dissection, arterial disruption with pseudoaneurysm) were repaired. CCA residual disease was reported as wall thickness (0.7-4.8 mm; mean, 1.7 +/- 0.7) and percent stenosis (16%-67%; mean, 32% +/- 8%) in all cases. Postoperative 30-day TIA, stroke, and death rates were analyzed. RESULTS: There were no clinically detectable postoperative thromboembolic events in this series. All 15 major defects (2.3%) identified with duplex scanning were successfully revised. These included 7 intimal flaps, 4 free-floating clots, 2 ICA stenoses, 1 ICA pseudoaneurysm, and 1 retrograde CCA dissection. Diameter reduction ranged from 40% to 90% (mean, 67 +/- 16%), and peak systolic velocity ranged from 69 to 497 cm/s (mean, 250 +/- 121 cm/s). Thirty-one patients (5%) with the highest residual wall thickness (>3mm) in the CCA and 19 (3%) with the highest CCA residual diameter reduction (>50%) did not have postoperative stroke or TIA. Overall postoperative stroke and mortality rates were 0.3% and 0.5%, respectively; combined stroke and mortality rate was 0.8%. One stroke was caused by hyperperfusion, and the other occurred as an extension of a previous cerebral infarct. No patients had TIAs. Two deaths were caused by myocardial infarction, and one death by respiratory insufficiency. CONCLUSION: We believe intraoperative duplex scanning had a major role in these improved results, because it enabled detection of clinically unsuspected significant lesions. Residual disease in the CCA does not seem to be a harbinger of stroke or TIA.
Keywords:
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号