首页 | 本学科首页   官方微博 | 高级检索  
检索        


Strecker stent in stenotic hemodialysis Brescia-Cimino arteriovenous fistulas
Authors:Bo?njakovi? Petar  Ivkovi? Tomislav  Ili? Miodrag  Aracki Sne?ana
Institution:(1) Vascular and Interventional Radiology Department, Institute of Radiology UMC, Braće Taskovića 48, 18000 NIŠ, Yugoslavia
Abstract:Flexible tantalum stents (Strecker) were used as an adjunct to percutaneous transluminal angioplasty (PTA) in the treatment of stenotic arterial or venous limbs of Brescia-Cimino hemodialysis fistulas. The diagnostic procedure was performed using retrograde fistulography. After PTA with unsatisfactory results, stents were placed in 5 patients with significant residual stenoses and poor fistula function. Within the mean follow-up period of 6.4 months (range 3–10 months) all fistulas were functioning. We conclude that Strecker stent is useful in the treatment of stenotic hemodialysis arteriovenous fistulas as an adjunct to PTA.
Keywords:Dialysis  fistulas  Interventional procedures  Percutaneous transluminal angioplasty  Veins  grafts  and prosthesis
本文献已被 SpringerLink 等数据库收录!