首页 | 本学科首页   官方微博 | 高级检索  
     

Semen analysis standardization: is there any problem in Polish laboratories?
作者姓名:Renata Walczak-Jedrzejowska  Katarzyna Marc hlewsks  Elzbieta Oszukowska  Eliza Filipiak  Leszek Bergier  Jolanta Slowikowska-Hilczer
作者单位:[1]Division of Andrology, Department of Andrology and Reproductive Endocrinology, Medical University of Lodz, 91-425 Lodz, Poland [2]Division of Reproductive Endocrinology, Department of Andrology and Reproductive Endocrinology, Medical University of Lodz, 91-425 Lodz, Poland [3]Diagnostyka Company Ltd, Medical Laboratories, 31-513 Cracow, Poland
基金项目:This work was supported by Medical University of Lodz (grant nos. 503/1- 1089-02/503 - 1 and 503/1-1089-03/503 - 1 ). The authors thank Mr Edward Lowczowski (MA), a native speaker, for manuscript language correction.
摘    要:The aim of the study was to determine the degree of compliance of Polish laboratories with World Health Organization (WHO) recommendations, with regard to semen analysis methodology. A survey requesting information about methods of semen analysis was distributed to employees of 55 laboratories. Respondents who had participated in external seminological workshops (31%) were termed certified respondents (CR), the remaining (69%)--non-certified respondents (NCR). Only one laboratory (6%) in the CR group and none in the NCR were compliant with WHO guidelines for methods and equipment used to evaluate seminal volume, sperm motility, concentration, vitality and morphology. Most problems were of volume measurement (weighing method was reported by 17% of CR and 10% of NCR) and staining method for sperm morphology (Papanicolau or Diff-Quik were found in 33% of CR and 23% of NCR). A three- or four-point grading of sperm motility was used by the majority of respondents; however, 17% of CR and 37% of NCR did not use a laboratory counter to tally spermatozoa. Although a haemocytometer method was used by 80% of laboratories in each group, the improved Neubauer chamber was used only by 42% of CR and 19% of NCR. In each group, 24% of laboratories did not perform a vitality test. Procedural errors and the interchangeable utilization of two or even three methods to analyse a given parameter was observed in both groups. The results indicate a need for standardisation of the methods and continuous, unified training in semen analysis in Polish laboratories.

关 键 词:实验室  精液量  标准化  波兰  世界卫生组织  精子活力  NCR  精子形态
收稿时间:2013-01-31
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号