首页 | 本学科首页   官方微博 | 高级检索  
检索        


Depth of sedation using Cerebral State Index in infants undergoing spinal anesthesia
Authors:NICOLA DISMA MD  PIETRO TUO MD  MARINELLA ASTUTO MD  † AND ANDREW J DAVIDSON MBBS MD FANZCA GradDipEpiBioStat  
Institution:Anaesthesia and Intensive Care, Gaslini Children's Hospital, Genoa, Italy;, Anaesthesia and Intensive Care, Policlinico University Hospital, Catania, Italy;and Department of Anaesthesia &Pain Management, Royal Children's Hospital, Melbourne, Australia
Abstract:Background: Infants are noted to frequently sleep during spinal anesthesia, with a concomitant fall in Bispectral Index. However, there are suggestions that EEG derived anesthesia depth monitors have inferior performance in infants. The aim of this study was to quantify the degree of sedation during spinal anesthesia in infants using another EEG derived measure of anesthesia effect – the Cerebral State Index (CSI). Methods: Twelve infants, <52 weeks postconceptual menstrual age, scheduled for bilateral inguinal hernia repair under spinal anesthesia were enrolled. Patients received a standard anesthetic protocol with a subarachnoid dose of 1 mg·kg?1 of levobupivacaine 0.5%. No premedication, sedatives, opioids or anticholinergics were administrated during the perioperative period and patients were left undisturbed during the surgical time, without tactile stimulation or loud auditory stimuli. CSI score (0–100) and bust suppression (BS) (0–100%) were continuously recorded during the surgical time and then statistically re‐evaluated. Results: In all patients the CSI fell during the procedure and there were significant levels of BS recorded by the CSI monitor. The BS occurred between 12 and 34 min after spinal anesthesia with the peak being at 30 min and mean onset time being 15 (2.6) min after spinal block. A statistical significant difference was found between the lowest mean CSI as well as the highest BS if compared with their baseline values. A negative correlation was found between CSI and BS. Conclusions: The degree of burst suppression detected by the CSI in our study supports the hypothesis that infants may have discontinuous patterns of EEG during spinal anesthesia similar to those seen during emergence from general anesthesia. Moreover, the limitations in the application of the adult algorithms to infant EEG may lead to an overestimation of the degree of sedation.
Keywords:spinal  infants  monitoring  sedation  cerebral state index  burst suppression
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号