首页 | 本学科首页   官方微博 | 高级检索  
     


Relationship of airborne microorganisms with the lung function and leucocyte levels of workers with a history of humidifier fever
Authors:E Kateman  D Heederik  T M Pal  M Smeets  T Smid  M Spitteler
Affiliation:Department of Environmental and Tropical Health, University Wageningen, The Netherlands.
Abstract:An influenza-like illness appeared recently among workers in a plant processing synthetic yarn. A humidifier, a cold-water spraying system, was the suspected cause. Lung function changes over the day and week and changes in blood leucocytes were studied among the workers from the suspected department and two reference populations. Exposure to colony-forming units of bacteria and fungi and to endotoxins was also monitored. The workers from the suspected department had statistically significantly lower lung functions on the first workday of the week than the referents. Their blood leucocytes were also raised statistically significantly. The exposure to fungi, bacteria, and endotoxins differed significantly between the various departments, but the measured levels were low. It was concluded that the observed effects were suggestive of a "Monday morning fever" type of reaction and that adverse effects occurred at exposure levels lower than those found to date in the literature.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号