首页 | 本学科首页   官方微博 | 高级检索  
检索        


Estimation of pulse pressure variation and cardiac output in patients having major abdominal surgery: a comparison between a mobile application for snapshot pulse wave analysis and invasive pulse wave analysis
Authors:Hoppe  Phillip  Gleibs  Fabian  Briesenick  Luisa  Joosten  Alexandre  Saugel  Bernd
Institution:1.Department of Anesthesiology, Center of Anesthesiology and Intensive Care Medicine, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany
;2.Department of Anesthesiology, CUB Erasme University Hospital, Université Libre de Bruxelles, 808 Route de Lennik, 1070, Brussels, Belgium
;3.Department of Anesthesiology and Intensive Care, H?pitaux Universitaires Paris-Sud, Université Paris-Sud, Université Paris-Saclay, H?pital De Bicêtre, Assistance Publique H?pitaux de Paris (AP-HP), Le Kremlin-Bicêtre, France
;4.Outcomes Research Consortium, Cleveland, OH, USA
;
Abstract:

Pulse pressure variation (PPV) and cardiac output (CO) can guide perioperative fluid management. Capstesia (Galenic App, Vitoria-Gasteiz, Spain) is a mobile application for snapshot pulse wave analysis (PWAsnap) and estimates PPV and CO using pulse wave analysis of a snapshot of the arterial blood pressure waveform displayed on any patient monitor. We evaluated the PPV and CO measurement performance of PWAsnap in adults having major abdominal surgery. In a prospective study, we simultaneously measured PPV and CO using PWAsnap installed on a tablet computer (PPVPWAsnap, COPWAsnap) and using invasive internally calibrated pulse wave analysis (ProAQT; Pulsion Medical Systems, Feldkirchen, Germany; PPVProAQT, COProAQT). We determined the diagnostic accuracy of PPVPWAsnap in comparison to PPVProAQT according to three predefined PPV categories and by computing Cohen’s kappa coefficient. We compared COProAQT and COPWAsnap using Bland-Altman analysis, the percentage error, and four quadrant plot/concordance rate analysis to determine trending ability. We analyzed 190 paired PPV and CO measurements from 38 patients. The overall diagnostic agreement between PPVPWAsnap and PPVProAQT across the three predefined PPV categories was 64.7% with a Cohen’s kappa coefficient of 0.45. The mean (±?standard deviation) of the differences between COPWAsnap and COProAQT was 0.6?±?1.3 L min??1 (95% limits of agreement 3.1 to ??1.9 L min??1) with a percentage error of 48.7% and a concordance rate of 45.1%. In adults having major abdominal surgery, PPVPWAsnap moderately agrees with PPVProAQT. The absolute and trending agreement between COPWAsnap with COProAQT is poor. Technical improvements are needed before PWAsnap can be recommended for hemodynamic monitoring.